Ultimate Cold-Electron Bolometer with Strong Electrothermal Feedback

نویسنده

  • Leonid Kuzmin
چکیده

ABSTRACT A novel concept of the Cold-Electron Bolometer (CEB) with strong electrothermal feedback has been proposed. The concept is based on direct electron cooling of the absorber that serves as negative electrothermal feedback for incoming signal. This feedback is analogous to TES (transition-edge sensor) but additional dc heating is replaced by deep electron cooling to minimum temperature. It could mean a principle breakthrough in realization of supersensitive detectors. Noise properties are considerably improved by decreasing the electron temperature. The loop gain of electrothermal feedback could exceed 1000. The response time is reduced by electrothermal feedback to 10ns in comparison with the intrinsic e-ph time constant of 10μs. The CEB gives opportunity to increase dynamic range by removing all incoming power from supersensitive absorber to the next stage of readout system (SQUID) with higher dynamic range. Saturation problems are not so severe for CEB as for TES: after exceeding the cooling power there is only slight deviation from linear dependence for voltage response. The full saturation comes at the level of 100pW when temperature of absorber achieves Tc of Al. Ultimate performance of the CEB is determined by shot noise of the signal readout. For relatively low background load P0 =10fW and quantization level Te= 50mK, the limit NEP is equal to 10W/Hz. The estimations show that it is realistic to achieve ultimate NEP at 100 mK with SQUID readout system and NEP=10W/Hz at 300mK for background load of 10fW. Applicability of the CEB to post-Herschel missions looks very promising.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voltage-Biased Superconducting Transition-Edge Bolometer with Strong Electrothermal Feedback Operated at 370 mK.

We present an experimental study of a composite voltage-biased superconducting bolometer (VSB). The tested VSB consists of a Ti-film superconducting thermometer (T(c) ~375 mK) on a Si substrate suspended by NbTi superconducting leads. A resistor attached to the substrate provides calibrated heat input into the bolometer. The current through the bolometer is measured with a superconducting quant...

متن کامل

1 Low noise cryogenic electronics : preamplifier configurations with feedback on the bolometer

We developed preamplifier configurations used to readout resistive bolometers such as those based on Neutron Transmuted Doped Germanium thermometers (so called NTD Ge thermometers)[1] or NbSi thin film thermometers [2, 3]. We introduce the impedance regulating preamplifier configuration. This configuration, is compared to previously proposed readout configurations with feedback on the bolometer...

متن کامل

Detection of Zeptojoule Microwave Pulses Using Electrothermal Feedback in Proximity-Induced Josephson Junctions.

We experimentally investigate and utilize electrothermal feedback in a microwave nanobolometer based on a normal-metal (Au_{x}Pd_{1-x}) nanowire with proximity-induced superconductivity. The feedback couples the temperature and the electrical degrees of freedom in the nanowire, which both absorbs the incoming microwave radiation, and transduces the temperature change into a radio-frequency elec...

متن کامل

Concept of a mixer based on a cold-electron bolometer

Chalmers Publication Library (CPL) offers the possibility of retrieving research publications produced at Chalmers University of Technology. It covers all types of publications: articles, dissertations, licentiate theses, masters theses, conference papers, reports etc. Since 2006 it is the official tool for Chalmers official publication statistics. To ensure that Chalmers research results are d...

متن کامل

Ultrasensitive and Wide-Bandwidth Thermal Measurements of Graphene at Low Temperatures

At low temperatures, the electron gas of graphene is expected to show both very weak coupling to thermal baths and rapid thermalization, properties which are desirable for use as a sensitive bolometer. We demonstrate an ultrasensitive, wide-bandwidth measurement scheme based on Johnson noise to probe the thermal-transport and thermodynamic properties of the electron gas of graphene, with a reso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010