Salvage of Intraoperative Deep Inferior Epigastric Perforator Flap Venous Congestion with Augmentation of Venous Outflow: Flap Morbidity and Review of the Literature

نویسندگان

  • Oscar Ochoa
  • Steven Pisano
  • Minas Chrysopoulo
  • Peter Ledoux
  • Gary Arishita
  • Chet Nastala
چکیده

BACKGROUND Breast reconstruction with deep inferior epigastric perforator (DIEP) flaps has gained considerable popularity due to reduced donor-site morbidity. Previous studies have identified the superficial venous system as the dominant outflow to DIEP flaps. DIEP flap venous congestion occurs if superficial venous outflow via the deep venous system is insufficient for effective flap drainage. Although augmentation of venous outflow through a second venous anastomosis may relieve venous congestion, effects on flap morbidity remain ill defined. METHODS A retrospective analysis of 1616 patients who underwent 2618 DIEP flap breast reconstructions between March 2005 and January 2012 was performed. Patients with intraoperative venous congestion underwent a second venous anastomosis. Preoperative demographic data and methods used to relieve venous congestion were recorded. Incidence of flap morbidity was calculated and compared with a group of 418 controls having 639 DIEP flap breast reconstructions with no venous congestion. RESULTS Venous augmentation was required to relieve venous congestion in 87 (3.3%) DIEP flaps on 81 patients. The superficial inferior epigastric vein or accompanying deep inferior epigastric venae comitantes was used to augment venous outflow. Preoperative comorbidities were similar between both groups. Patients requiring a second venous anastomosis had a longer operative time and length of hospital stay. Overall, flap morbidity, delayed wound healing, fat necrosis, and flap loss were similar to controls. CONCLUSIONS Arterial and venous anatomies play unique roles in flap reliability. DIEP flap venous congestion must be treated expeditiously with venous augmentation to relieve venous congestion and mitigate flap morbidity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel technique for venous augmentation in a free deep inferior epigastric perforator flap.

Venous congestion in a free deep inferior epigastric perforator flap threatens the viability of the flap and can lead to eventual flap loss. We describe a novel technique for flap salvage by anastomosing the ipsilateral superficial inferior epigastric vein to a venae comitantes of the deep inferior epigastric pedicle. When recognized intraoperatively, venous congestion can be relieved immediate...

متن کامل

A Novel Strategy to Supercharge a Deep Inferior Epigastric Artery Perforator Flap after Port-a-Cath Removal

Autologous breast reconstruction using the deep inferior epigastric artery perforator (DIEP) flap has become increasingly popular because of its unique advantages. However, compared with some other forms of abdominal-based autologous reconstruction, DIEP flaps are associated with an increased risk of venous congestion. Many techniques-or lifeboats-have been introduced to diagnose and treat this...

متن کامل

CASE REPORT Case Report and Review of the Literature: Deep Inferior Epigastric Perforator Flap for Breast Reconstruction After Abdominal Recontouring

OBJECTIVE The report herein presents a case of a 49-year-old woman with left breast cancer who presented seeking immediate autologous reconstruction. Surgical history included an abdominal hysterectomy and an abdominal contouring procedure. This is a first description of a deep inferior epigastric perforator flap after abdominal wall manipulation of this magnitude. METHODS Computed tomographi...

متن کامل

Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction without Microsurgery Fellowship Training

BACKGROUND Deep inferior epigastric artery perforator (DIEP) flap breast reconstruction requires complex microsurgical skills. Herein, we examine whether DIEP flap breast reconstruction can be performed safely without microsurgical fellowship training. METHODS A total of 28 patients and 34 DIEP flaps were included in the study. We reviewed the medical records of patients for donor site and fl...

متن کامل

A single center comparison of one versus two venous anastomoses in 564 consecutive DIEP flaps: investigating the effect on venous congestion and flap survival.

BACKGROUND Venous complications have been reported as the more frequently encountered vascular complications seen in the transfer of deep inferior epigastric artery (DIEA) perforator (DIEP) flaps, with a variety of techniques described for augmenting the venous drainage of these flaps to minimize venous congestion. The benefits of such techniques have not been shown to be of clinical benefit on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2013