Endothelial cell recovery between comparator polymer-based drug-eluting stents.

نویسندگان

  • Michael Joner
  • Gaku Nakazawa
  • Aloke V Finn
  • Shawn Chin Quee
  • Leslie Coleman
  • Eduardo Acampado
  • Patricia S Wilson
  • Kristi Skorija
  • Qi Cheng
  • Xin Xu
  • Herman K Gold
  • Frank D Kolodgie
  • Renu Virmani
چکیده

OBJECTIVES The purpose of this study was to assess trends in endothelial coverage and recovery among leading polymer-based drug-eluting stents (DES). BACKGROUND Autopsy studies of human U.S. Food and Drug Administration (FDA)-approved DES implanted coronary arteries suggest that complications of late stent thrombosis are associated with incomplete endothelial coverage of struts. METHODS Rabbits received sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), and everolimus-eluting stents (EES) for 14 or 28 days along with MULTI-LINK (ML) Vision control stents. Endothelial coverage above and between struts was measured by morphometric analysis of images acquired through en face scanning electron microscopy. Dual fluorescent immunolabeling was performed for platelet-endothelial cell adhesion molecule (PECAM)-1 and thrombomodulin (TM), factors involved in cell-to-cell contact and thrombogenicity, respectively. In a separate analysis, the endothelial mitogen, vascular endothelial growth factor (VEGF), was also assessed. RESULTS Varying rates of endothelialization among comparator DES were most notable at 14 days, where coverage above struts remained poor in SES, PES, and ZES (or=70%), whereas no significant differences were observed at 28 days. Select DES with poor endothelialization showed a further reduced expression of PECAM-1. All DES showed an absence or weak expression of the antithrombotic cofactor TM. Incomplete endothelialization in select DES was further associated with increased VEGF secretion and messenger ribonucleic acid levels at 14 days, providing evidence of a transitional healing surface. CONCLUSIONS The present study marks the first comparator analysis of endothelial coverage in leading polymeric DES, supporting disparities in arterial healing based on endothelial regrowth and recovery, favoring newer designs over the current generation of FDA-approved stents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents.

BACKGROUND Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. METHODS AND RESULTS We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelializ...

متن کامل

Evaluation of polymer-based comparator drug-eluting stents using a rabbit model of iliac artery atherosclerosis.

BACKGROUND Although atherosclerotic models, especially in the rabbit, have existed for a long time, a comparative study of various drug-eluting stent (DES) implantations in atherosclerotic arteries have not been systematically studied. METHODS AND RESULTS New Zealand White rabbits (n=44) with induced atheroma received bilateral iliac artery stents: bare metal stent (BMS) (Driver) or a stent e...

متن کامل

Global gene expression analysis of the effects of vinblastine on endothelial cells, when eluted from a thermo-responsive polymer.

In-stent restenosis remains a significant problem associated with bare metal stents. This drawback has prompted research into improving stent design and the development of novel coatings, including drug-eluting stents. A number of drug-eluting stents are currently on the market; however, the success rate of these stents in complex situations has been found to be quite low. Thus, there remains p...

متن کامل

Polymer-free sirolimus-eluting versus polymer-based paclitaxel-eluting stents: an individual patient data analysis of randomized trials.

INTRODUCTION AND OBJECTIVES The angiographic and clinical efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents remain a matter of debate. We sought to investigate angiographic and clinical measures of efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents. METHODS Patient data from the randomized intracoronary stent...

متن کامل

Progress in treatment by percutaneous coronary intervention: the stent of the future.

First generation drug-eluting stents have considerably reduced in-stent restenosis and broadened the applications of percutaneous coronary interventions for the treatment of coronary artery disease. The polymer is an integral part of drug-eluting stents in that, it controls the release of an antiproliferative drug. The main safety concern of first generation drug-eluting stents with permanent p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 52 5  شماره 

صفحات  -

تاریخ انتشار 2008