Light-emitting diode fluorescence microscopy for tuberculosis diagnosis: a meta-analysis.
نویسندگان
چکیده
Light-emitting diode fluorescence microscopy (LED-FM) is recommended by the World Health Organization to replace conventional Ziehl-Neelsen microscopy for pulmonary tuberculosis diagnosis. Uptake of LED-FM has been slow. One reason is its reported loss of specificity compared with Ziehl-Neelsen microscopy. We aimed to determine the diagnostic accuracy of LED-FM for tuberculosis detection and explore potential factors that might affect its performance.A comprehensive search strategy based on pre-specified criteria was employed to identify eligible studies between January 1, 2000 and April 1, 2014 in 11 databases. Standardised study selection, data extraction and quality assessment were conducted. Pooled sensitivity and specificity of LED-FM using culture as the reference standard were estimated through meta-analyses using a bivariate random-effects model. Investigation of heterogeneity was performed by subgroup analyses.We identified 12 unique studies, half of which were from peripheral healthcare facilities. LED-FM achieved a pooled sensitivity of 66.9% (95% CI 60.5-72.7%) and pooled specificity of 96.8% (95% CI 93.1-98.6%). A pooled sensitivity of 53.0% (95% CI 42.8-63.0%) and pooled specificity of 96.1% (95% CI 86.0-99.0%) were obtained by LED-FM among HIV-infected patients. Study methodology factors and differences in the LED-FM procedure or device could also affect the performance.LED-FM specificity is high and should not be a barrier to device introduction, particularly among peripheral healthcare settings where this technology is meant to be used. Sensitivity is reduced in HIV-infected patients.
منابع مشابه
Led Fluorescence Microscopy: Leads the Future of Rapid and Effective Pulmonary Tuberculosis Diagnosis
Early diagnosis and appropriate treatment play an important role in combating the mortality and morbidity caused by Tuberculosis and a rapid, reliable microscopy that can detect acid fast bacilli can be a very useful diagnostic modality. We have evaluated the performance of Light Emitting Diode Fluorescence Microscopy as an alternative to the existing conventional methods in the diagnosis of Pu...
متن کاملUsefulness of light emitting diode (LED) fluorescent microscopy as a tool for rapid and effective method for the diagnosis of pulmonary tuberculosis.
BACKGROUND Tuberculosis remains world's leading cause of death from a single infectious agent. Fluorescence microscopy offers well-described benefits, comparing with brightfield microscopy, for the evaluation sputum smear samples for tuberculosis. We evaluated the diagnostic performance of fluorescence microscopy, using novel Light Emitting Diode (LED) technology as an alternative to the conven...
متن کاملLED fluorescence microscopy for diagnosis of tuberculosis in countries with high disease burden
Sputum light microscopy is still the cornerstone of tuberculosis (TB) diagnosis in developing countries. The advent of fluorescence microscope (FM) was a major step forward in the direction of improved diagnosis of TB. But the high cost of the mercury lamp and its maintenance cost gave way to a cheaper alternative, i.e. light-emitting diode (LED). Thus, increased sensitivity, low cost and more ...
متن کاملComparison of LED and Conventional Fluorescence Microscopy for Detection of Acid Fast Bacilli in a Low-Incidence Setting
INTRODUCTION Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. METHODS In a nested case-control study, we compared diagnostic accuracy and time required to read slides with...
متن کاملMicroscopy as a diagnostic tool in pulmonary tuberculosis.
Tuberculosis continues to cast a huge impact on humanity with its high incidence and mortality, especially in developing countries. For tuberculosis case detection, microscopy continues to be indispensible, given its low cost, rapidity, simplicity of procedure and high specificity. Modifications have attempted to improve the sensitivity of microscopy which include: concentration methods such as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2016