Efficient sweep buffering in swept source optical coherence tomography using a fast optical switch
نویسندگان
چکیده
We describe a novel buffering technique for increasing the A-scan rate of swept source optical coherence tomography (SSOCT) systems employing low duty cycle swept source lasers. This technique differs from previously reported buffering techniques in that it employs a fast optical switch, capable of switching in 60 ns, instead of a fused fiber coupler at the end of the buffering stage, and is therefore appreciably more power efficient. The use of the switch also eliminates patient exposure to light that is not used for imaging that occurs at the end of the laser sweep, thereby increasing the system sensitivity. We also describe how careful management of polarization can remove undesirable artifacts due to polarization mode dispersion. In addition, we demonstrate how numerical compensation techniques can be used to modify the signal from a Mach-Zehnder interferometer (MZI) clock obtained from the original sweep to recalibrate the buffered sweep, thereby reducing the complexity of systems employing lasers with integrated MZI clocks. Combining these methods, we constructed an SSOCT system employing an Axsun technologies laser with a sweep rate of 100kHz and 6dB imaging range of 5.5mm. The sweep rate was doubled with sweep buffering to 200 kHz, and the imaging depth was extended to 9 mm using coherence revival. We demonstrated the feasibility of this system by acquiring images of the anterior segments and retinas of healthy human volunteers.
منابع مشابه
Frequency Comb Swept Lasers for Optical Coherence Tomography
We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FCFDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively, over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the c...
متن کاملHigh-speed, high-resolution optical coherence tomography retinal imaging with a frequency-swept laser at 850 nm.
High-speed, high-resolution optical coherence tomography (OCT) imaging of the human retina is demonstrated using a frequency-swept laser at 850 nm. A compact external cavity semiconductor laser design, optimized for swept-source ophthalmic OCT, is described. The laser enables an effective 16 kHz sweep rate with >10 mm coherence length and a tuning range of approximately 35 nm full width at half...
متن کاملCorrection of sampling errors due to laser tuning rate fluctuations in swept-wavelength interferometry.
The frequency-sampling method is widely used to accommodate nonlinear laser tuning in swept-wavelength interferometric techniques such as optical frequency domain reflectometry (OFDR) and swept-wavelength optical coherence tomography (OCT). In this paper we analyze the frequency-sampling method and identify two sources of sampling errors. One source of error is the limit of an underlying approx...
متن کاملWavelength swept amplified spontaneous emission source.
We present a new, alternative approach to realize a wavelength swept light source with no fundamental limit to sweep speed. Amplified spontaneous emission (ASE) light alternately passes a cascade of optical gain elements and tunable optical bandpass filters. We show that for high sweep speeds, the control signal for the different filters has to be applied with a defined, precise phase delay on ...
متن کاملFull-Field Optical Coherence Tomography Using Galvo Filter-Based Wavelength Swept Laser
We report a wavelength swept laser-based full-field optical coherence tomography for measuring the surfaces and thicknesses of refractive and reflective samples. The system consists of a galvo filter-based wavelength swept laser and a simple Michelson interferometer. Combinations of the reflective and refractive samples are used to demonstrate the performance of the system. By synchronizing the...
متن کامل