Accuracy of ICD-9-CM coding for the identification of patients with acute ischemic stroke: effect of modifier codes.
نویسنده
چکیده
BACKGROUND AND PURPOSE Discharge ICD-9-CM (International Classification of Diseases, 9th Revision, Clinical Modification) codes have been used to identify patients with acute stroke for epidemiological, quality of care, and cost studies. The aim of this study was to determine if the accuracy of the primary ICD-9-CM codes for ischemic stroke is improved by modifier codes and how specific codes reflect stroke subtype diagnoses. METHODS Available hospital charts for all patients discharged from a single hospital between May 1995 and June 1997 with ICD-9-CM codes 433 (occlusion and stenosis of precerebral arteries), 434 (occlusion of cerebral arteries), or 436 (acute but ill-defined cerebrovascular disease) listed in the first position were reviewed. The primary discharge diagnosis was verified, and a presumed stroke subtype was assigned on the basis of information provided in the medical record. RESULTS Charts were available for 175 of the 198 identified patients (88%). Of these, 61% had an acute ischemic stroke (code 433, 4%; 434, 82%; 436, 79%) with the remaining patients having other conditions. Of the 130 patients with a modifier code indicating cerebral infarction, 79% had an acute stroke; of the 45 patients with a modifier code indicating an absence of cerebral infarction, 7% had acute stroke (sensitivity, 0.97; specificity, 0.60). The codes with the highest proportions of ischemic stroke cases were 434.11 (embolic occlusion of cerebral arteries with infarction, 85%), 434.91 (unspecified occlusion of precerebral arteries with infarction, 82%), and 436 (79%), with a combined sensitivity of 0.81 and specificity of 0.90. On review, 73% of patients with code 434.11 had embolic strokes, and 47% of those with code 436 had an identified stroke cause. Of patients with code 434.91, 39% had stroke of uncertain cause, 25% "lacunar," 17% atherothrombosis, and 15% embolism. CONCLUSIONS Despite the use of modifier codes, 15% to 20% of patients with the indicated primary ICD-9-CM codes have conditions other than acute ischemic stroke. Although the proportion of patients with acute stroke increased from 61% to 79% with the use of modifier codes, the inclusion of modifier codes did not have an appreciable effect on the accuracy of the coding if patients with code 433 are excluded. Assignment of presumed ischemic stroke subtype is particularly inaccurate.
منابع مشابه
Accuracy of ICD‐9‐CM Codes by Hospital Characteristics and Stroke Severity: Paul Coverdell National Acute Stroke Program
BACKGROUND Epidemiological and health services research often use International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes to identify patients with clinical conditions in administrative databases. We determined whether there are systematic variations between stroke patient clinical diagnoses and ICD-9-CM codes, stratified by hospital characteristics and ...
متن کاملStroke: who's counting what?
INTRODUCTION Patients with stroke are often selected for epidemiological reporting and research using ICD-9-CM (ICD-9) diagnostic codes. This study addresses the accuracy of these codes in identifying patients with stroke. METHODS A sample of 279 patients with new stroke and 392 non-stroke (no evidence of new stroke) patients were identified by medical record review from 11 Veterans Affairs M...
متن کاملCoding of stroke and stroke risk factors using international classification of diseases, revisions 9 and 10.
BACKGROUND AND PURPOSE Surveillance is necessary to understand and meet the future demands stroke will place on health care. Administrative data are the most accessible data source for stroke surveillance in Canada. The International Classification of Diseases, 10th revision (ICD-10) coding system has potential improvements over ICD-9 for stroke classification. Our purpose was to compare hospit...
متن کاملAdministrative data underestimate acute ischemic stroke events and thrombolysis treatments: Data from a multicenter validation survey in Italy
BACKGROUND Informing health systems and monitoring hospital performances using administrative data sets, mainly hospital discharge data coded according to International-Classification-Diseases-9edition-Clinical-Modifiers (ICD9-CM), is now commonplace in several countries, but the reliability of diagnostic coding of acute ischemic stroke in the routine practice is uncertain. This study aimed at ...
متن کاملThe Quality of Coding Medical Records of Cancer Patients Based on ICD-10 in Hospitals of Hormozgan University of Medical Sciences
Introduction: The aim of this study was to determine the status of ICD-10 codes assigned to cancer patients' medical records in terms of three attributes of accuracy, completeness, and timeliness. Method: in this cross-sectional descriptive study, 374 medical files with C00-D48 diagnosis codes were selected through stratified sampling. Data gathering tool was a researcher-made checklist consist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 29 8 شماره
صفحات -
تاریخ انتشار 1998