Tone-dependent coronary arterial-venous pressure differences at the cessation of venous outflow during long diastoles.

نویسندگان

  • S Satoh
  • F J Klocke
  • J M Canty
چکیده

BACKGROUND The origin and magnitude of the back pressure opposing diastolic coronary inflow remain controversial. The arterial pressure at which coronary inflow stops during a prolonged diastole, ie, "zero-flow pressure," is higher than coronary venous pressure. However, because of capacitive discharge as distending pressure falls, flow at the microcirculatory level exceeds inflow, and coronary outflow ceases later than inflow. If coronary arterial pressure continues to exceed venous pressure at the point of venous flow cessation, zero-flow pressure cannot be an artifact of capacitive discharge. METHODS AND RESULTS Coronary inflow and outflow, arterial pressure, and right atrial pressure have been measured during long diastoles in closed-chest dogs chronically instrumented with volumetric flow probes on the great cardiac vein or coronary sinus as well as the circumflex artery. Although venous outflow continued for 1 to 4 seconds after arterial inflow ceased, coronary artery pressure at the point of venous flow cessation (Pfv = 0) always exceeded right atrial pressure (13 +/- 1.3 mm Hg [SEM] vs 6 +/- 0.7 mm Hg, P < .001). When vasomotor tone was augmented using vasopressin, the diastolic pressure-flow relation shifted to the right, with Pfv = 0 increasing to 21 +/- 2.4 mm Hg despite an unchanged right atrial pressure (6 +/- 0.5 mm Hg). CONCLUSIONS Transcoronary pressure differences persist when venous outflow stops and are larger when vasomotor tone is augmented. Measurements of zero-flow pressure that exceed venous pressure cannot be considered an artifact of continuing capacitive discharge after the cessation of arterial inflow. Diastolic coronary back pressure exceeds right atrial pressure and is tone dependent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary diastolic pressure-flow relation and zero flow pressure explained on the basis of intramyocardial compliance.

In the controversy about the mechanisms determining the high zero flow pressures and the further interpretation of coronary diastolic pressure flow relations, this paper takes a stand in favor of intramyocardial compliance as the primary cause of the high zero flow pressures. An attempt has been made to estimate the compliance distribution within the coronary circulation and to show the specifi...

متن کامل

Diameter change and pressure-red blood cell velocity relations in coronary microvessels during long diastoles in the canine left ventricle.

The objective of this study was to determine whether coronary vascular resistance remains constant during long diastoles and whether critical closure of arterial microvessels occurs at zero-flow pressure. For this purpose, we directly measured internal diameters and red blood cell velocities in arterial and venous coronary microvessels during long diastoles under maximal vasodilation. The epica...

متن کامل

Cell Velocity Relations in Coronary Microvessels During Long Diastoles in the Canine Left Ventricle

The objective of this study was to determine whether coronary vascular resistance remains constant during long diastoles and whether critical closure of arterial microvessels occurs at zero-flow pressure. For this purpose, we directly measured internal diameters and red blood cell velocities in arterial and venous coronary microvessels during long diastoles under maximal vasodilation. The epica...

متن کامل

Response to the article by Klocke et al. on "Coronary pressure-flow relationships: controversial issues and probable implications".

On the basis of the material discussed, our current assessments of the controversial points mentioned at the beginning of this article may be summarized as follows: Pf = 0, the minimum back pressure to coronary flow associated with a measurable conductance, is indeed greater than coronary outflow pressure (and usually left ventricular diastolic pressure, as well). Pf = 0 needs to be taken into ...

متن کامل

Zero-flow pressures and pressure-flow relationships during single long diastoles in the canine coronary bed before and during maximum vasodilation. Limited influence of capacitive effects.

The proposal that diastolic coronary flow is regulated by an intramyocardial "back-pressure" that substantially exceeds coronary venous and ventricular diastolic pressures has been examined in an open-chest canine preparation in which instantaneous left circumflex pressure and flow could be followed to cessation of inflow during prolonged diastoles. Despite correlation coefficients consistently...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 88 3  شماره 

صفحات  -

تاریخ انتشار 1993