A necessary evil? Intra-abdominal hypertension complicating burn patient resuscitation
نویسندگان
چکیده
OBJECTIVE Severe burns are devastating injuries that result in considerable systemic inflammation and often require resuscitation with large volumes of fluid. The result of massive resuscitation is often raised intra-abdominal pressures leading to Intra-abdominal hypertension (IAH) and the secondary abdominal compartment syndrome. The objective of this study is to conduct (1) a 10 year retrospective study to investigate epidemiological factors contributing to burn injuries in Alberta, (2) to characterize fluid management and incidence of IAH and ACS and (3) to review fluid resuscitation with a goal to identify optimal strategies for fluid resuscitation. DESIGN A comprehensive 10-year retrospective review of burn injuries from 1999. OUTCOME MEASURES Age, sex, date, mechanism of injury, location of incident, on scene vitals and GCS, type of transport to hospital and routing, ISS, presenting vitals and GCS, diagnoses, procedures, complications, hospital LOS, ICU LOS, and events surrounding the injury. RESULTS One hundred and seventy five patients (79.4% M, 20.6% F) were identified as having traumatic burn injuries with a mean ISS score of 21.8 (±8.3). The mean age was 41.6 (±17.5) (range 14-94) years. Nearly half (49.7%) of patients suffered their injuries at home, 17.7% were related to industrial incidents and 14.3% were MVC related. One hundred and ten patients required ICU admission. ICU LOS 18.5 (±8.8) days. Hospital LOS 38.0 (±37.8) days. The mean extent of burn injury was 31.4 (±20.9) % TBSA. Nearly half of the patients suffered inhalational injuries (mild 12.5%, moderate 13.7%, severe 9.1%). Thirty-nine (22.2%) of patients died from their injuries. Routine IAP monitoring began in September, 2005 with 15 of 28 patients having at least two IAP measurements. The mean IAP was 16.5 (±5.7) cm H2O (range: 1-40) with an average of 58 (±97) IAP measurements per patient. Those patients with IAP monitoring had an average TBSA of 35.0 (±16.0)%, ISS of 47.5 (±7.5). The mean 48 hr fluid balance was 25.6 (±11.1)L exceeding predicted Parkland formula estimates by 86 (±32)%. CONCLUSIONS Further evaluation of IAP monitoring is needed to further characterize IAP and fluid resuscitation in patients with burn injuries.
منابع مشابه
A prospective, randomized evaluation of intra-abdominal pressures with crystalloid and colloid resuscitation in burn patients.
BACKGROUND The volume of resuscitation in burn patients has been shown to correlate with intra-abdominal pressure (IAP). Limiting volume may reduce consequences of IAP and abdominal compartment syndrome. Colloid resuscitation has been previously shown to limit the volume required initially after burn. METHODS Thirty-one patients were prospectively followed. Inclusion criteria were a burn of 2...
متن کاملAbdominal compartment syndrome monitoring in major burn patients with Siriraj device catheter.
Abdominal compartment syndrome (ACS) is consistently reported to have significant morbidity and mortality. Major burn patients who receive massive fluid resuscitation are at high-risk for this condition. Close monitoring of ACS is necessary for these patients. Prolonged unrelieved intra-abdominal pressure (IAP) at greater than 20 mmHg can produce significant morbidity and mortality. The most wi...
متن کاملA systematic review on intra-abdominal pressure in severely burned patients.
OBJECTIVE Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are complications that may occur in severely burned patients. Evidenced based medicine for these patients is in its early development. The aim of this study was to provide an overview of literature regarding IAH and ACS in severely burned patients. METHODS A systematic search was performed in Cochrane Centra...
متن کاملAn overview on fluid resuscitation and resuscitation endpoints in burns: Past, present and future. Part 2 - avoiding complications by using the right endpoints with a new personalized protocolized approach.
While organ hypoperfusion caused by inadequate resuscitation has become rare in clinical practice due to the better understanding of burn shock pathophysiology, there is growing concern that increased morbidity and mortality related to over-resuscitation induced by late 20th century resuscitation strategies based on urine output, is occurring more frequently in burn care. In order to reduce com...
متن کاملAbdominal Compartment Syndrome complicating massive hemorrhage from an unusual presentation of ruptured ectopic pregnancy.
Abdominal Compartment Syndrome (ACS) is characterized by intra-abdominal hypertension (IAH), elevation and splinting of the diaphragm, high pleural pressure, and poor venous return to the heart, producing low cardiac output and shock which, in turn, results in poor venous return across the capillaries to set in a vicious cycle. Unless the Intra-abdominal pressure is reduced quickly by urgent su...
متن کامل