Ultrashort echo imaging of cyclically loaded rabbit patellar tendon.

نویسندگان

  • Matthew F Koff
  • Sarah L Pownder
  • Parina H Shah
  • Lim Wei Yang
  • Hollis G Potter
چکیده

Tendinopathy affects individuals who perform repetitive joint motion. Magnetic resonance imaging (MRI) is frequently used to qualitatively assess tendon health, but quantitative evaluation of inherent MRI properties of loaded tendon has been limited. This study evaluated the effect of cyclic loading on T₂* values of fresh and frozen rabbit patellar tendons using ultra short echo (UTE) MRI. Eight fresh and 8 frozen rabbit lower extremities had MR scans acquired for tendon T₂* evaluation. The tendons were then manually cyclically loaded for 100 cycles to 45 N at approximately 1 Hz. The MR scanning was repeated to reassess the T₂* values. Analyses were performed to detect differences of tendon [Formula: see text] values between fresh and frozen samples prior to and after loading, and to detect changes of tendon T₂* values between the unloaded and loaded configurations. No difference of T₂* was found between the fresh and frozen samples prior to or after loading, p=0.8 and p=0.1, respectively. The tendons had significantly shorter T₂* values, p=0.023, and reduced T₂* variability, p=0.04, after cyclic loading. Histologic evaluation confirmed no induced tendon damage from loading. Shorter T₂* , from stronger spin-spin interactions, may be attributed to greater tissue organization from uncrimping of collagen fibrils and lateral contraction of the tendon during loading. Cyclic tensile loading of tissue reduces patellar tendon T₂* values and may provide a quantitative metric to assess tissue organization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of freeze-thawing on magnetic resonance imaging T2* of freshly harvested bovine patellar tendon.

BACKGROUND Analysis of fresh specimens in research studies is ideal; however, it is often necessary to freeze samples for evaluation at a later time. Limited evaluation of the effect of freeze-thawing of tendon tissue samples on inherent magnetic resonance imaging (MRI) parameters, such as ultrashort echo time (UTE) T2* values, have been performed to date. METHODS This study performed UTE MRI...

متن کامل

Fabrication of novel tubular scaffold for tendon repair from chitosan in combination with zinc nanoparticles

Chitosan bears numerous properties, such as biocompatibility, biodegradability and non-toxicity making it suitable for use in different biomedical fields. Zinc (Zn) is required for fibroblasts proliferation and collagen synthesis as essential elements of wound healing. Its nanoparticles are well known for their capability to enhance wound healing by cell adhesion and migration improvement throu...

متن کامل

Ultrasound echo is related to stress and strain in tendon.

The mechanical behavior of tendons has been well studied in vitro. A noninvasive method to acquire mechanical data would be highly beneficial. Elastography has been a promising method of gathering in vivo tissue mechanical behavior, but it has inherent limitations. This study presents acoustoelasticity as an alternative ultrasound-based method of measuring tendon stress and strain by reporting ...

متن کامل

Magnetic Resonance in Medicine 000:000–000 (2011) Ultrashort Echo Time Imaging Using Pointwise Encoding Time Reduction With Radial Acquisition (PETRA)

Sequences with ultrashort echo times enable new applications of MRI, including bone, tendon, ligament, and dental imaging. In this article, a sequence is presented that achieves the shortest possible encoding time for each k-space point, limited by pulse length, hardware switching times, and gradient performance of the scanner. In pointwise encoding time reduction with radial acquisition (PETRA...

متن کامل

Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA).

Sequences with ultrashort echo times enable new applications of MRI, including bone, tendon, ligament, and dental imaging. In this article, a sequence is presented that achieves the shortest possible encoding time for each k-space point, limited by pulse length, hardware switching times, and gradient performance of the scanner. In pointwise encoding time reduction with radial acquisition (PETRA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 47 13  شماره 

صفحات  -

تاریخ انتشار 2014