First basic performance evaluation of the XE-2100 haematology analyser

نویسندگان

  • Izumi Tsuda
  • Masayuki Hino
  • Takayuki Takubo
  • Tomoko Katagami
  • Hiroshi Kubota
  • Seiki Kawai
  • N. Tatsumi
چکیده

The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2K. Reproducibility, carryover, stability during storage at 4 degrees C and room temperature, and accuracy were evaluated. In this evaluation, reproducibility was good and little carryover was found. Accurate measurements were possible for up to 48 h of storage. A good correlation between findings with the XE-2100 and SE-9000 haematology analysers was found for complete blood count on 210 samples tested. The leukocyte differential obtained with the XE-2100 correlated well with eye counts and with the results obtained with the SE-9000 automated haematology analyser, with r values over 0.9 for the percentages of neutrophils, lymphocytes and eosinophils. The precision and accuracy of VRBC and reticulocyte counts by the XE-2100 were satisfactory. We used the XE-2100 to obtain differential counts for bone marrow aspirates, and good correlations with manual differentials were obtained for total nucleated cell count, percentage of myeloid cells and percentage of erythroid cells. The performance of the XE-2100 was excellent, and this instrument should be able to provide reliable data to clinical laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated counting of white blood cells in synovial fluid.

OBJECTIVES To evaluate the performance of automated leucocyte (white blood cell; WBC) counting by comparison with manual counting. METHODS The number of WBC was determined in heparinized synovial fluid samples by the use of (i) a standard urine cytometer (Kova) and a microscope (reference method) and (ii) a haematology analyser (Sysmex XE-2100; WBC/BASO and DIFF channels). Imprecision within ...

متن کامل

Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.

Although haematology analysers provide reliable full blood counts, they are known to be inaccurate at enumerating platelets in severe thrombocytopenia. If the thresholds for platelet transfusion, currently set at 10 x 10(9)/l, are to be further reduced, it is vital that the limitations of current analysers are fully understood. The aim of this large multicentre study was to determine the accura...

متن کامل

Automated counting of nucleated red blood cells in blood samples of newborns.

Nucleated red blood cells (NRBC) in blood samples interfere with the white blood cell (WBC) count on many types of automated haematology analysers. This makes it necessary to correct the WBC count by counting NRBC microscopically. This report describes the evaluation of two analysers, the Cell-Dyn 4000 and the Sysmex XE-2100, which use new techniques to recognize and enumerate NRBC. We conclude...

متن کامل

New Red Cell Parameters on the Sysmex XE-2100 as Potential Markers of Functional Iron Deficiency

The ideal approach to monitor the haematological response of patients with the anaemia associated with chronic renal failure during erythropoietin therapy is controversial. The reticulocyte haemoglobin content (CHr) and percentage hypochromic red cells (% Hypo) may be used as sensitive and specific indicators of functional iron deficiency in clinical situations with otherwise normal red cell in...

متن کامل

Evaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte

Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods and Management in Chemistry

دوره 21  شماره 

صفحات  -

تاریخ انتشار 1999