Radioactive contamination of scintillators
نویسندگان
چکیده
Low counting experiments (search for double β decay and dark matter particles, measurements of neutrino fluxes from different sources, search for hypothetical nuclear and subnuclear processes, low background α, β, γ spectrometry) require extremely low background of a detector. Scintillators are widely used to search for rare events both as conventional scintillation detectors and as cryogenic scintillating bolometers. Radioactive contamination of a scintillation material plays a key role to reach low level of background. Origin and nature of radioactive contamination of scintillators, experimental methods and results are reviewed. A programme to develop radiopure crystal scintillators for low counting experiments is discussed briefly.
منابع مشابه
Radioactive contamination of ZnWO4 crystal scintillators
The radioactive contamination of ZnWO4 crystal scintillators has been measured deep underground at the Gran Sasso National Laboratory (LNGS) of the INFN in Italy with a total exposure 3197 kg × h. Monte Carlo simulation, time-amplitude and pulse-shape analyses of the data have been applied to estimate the radioactive contamination of the ZnWO4 samples. One of the ZnWO4 crystals has also been te...
متن کاملConceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements
The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...
متن کاملDevelopment of RadRob15, A Robot for Detecting Radioactive Contamination in Nuclear Medicine Departments
Accidental or intentional release of radioactive materials into the living or working environment may cause radioactive contamination. In nuclear medicine departments, radioactive contamination is usually due to radionuclides which emit high energy gamma photons and particles. These radionuclides have a broad range of energies and penetration capabilities. Rapid detection of radioactive contami...
متن کاملSearch for rare processes with ZnWO4 crystal scintillators
Radiopure ZnWO4 crystal scintillators with mass (0.1–0.7 kg) have been developed and put in measurement in the Gran Sasso National Laboratories of the INFN to search for rare processes. The radioactive contamination of the crystals have been estimated and the double beta decay of zinc and tungsten isotopes was searched for, reaching a sensitivity at the level of 1018 − 1021 yr; in addition a ne...
متن کاملBiPo PROTOTYPE FOR SuperNEMO RADIOPURITY MEASUREMENTS
The BiPo project is dedicated to the measurement of extremely low radioactive contaminations of SuperNEMO ββ source foils (Tl < 2 μBq/kg and Bi < 10 μBq/kg). A modular BiPo1 prototype with its 20 modules and its shielding test facility is running in the Modane Underground Laboratory since February, 2008. The goal of this prototype is to study the backgrounds and particularly the surface contami...
متن کامل