Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?

نویسندگان

  • Ferdinand Vogt
  • Steffen Pfeiffer
  • Angelo Maria Dell'Aquila
  • Theodor Fischlein
  • Giuseppe Santarpino
چکیده

OBJECTIVES Aortic valve replacement (AVR) with sutureless bioprostheses has become an alternative to conventional AVR for patients with intermediate to high operative risk. However, this technique is associated with an increased risk of postoperative conduction disorders. METHODS We analysed 258 patients who underwent AVR with the Perceval prosthesis from July 2010 to September 2014 at our centre. Electrocardiography were obtained at baseline to record preoperatively the presence of conduction disorders. Preoperative risk factors, intraoperative procedures and complications (61 variables) were compared between patients with permanent pacemaker (PPM group) and without (no-PPM group) need for postoperative PPM implantation. RESULTS One hundred and sixty-nine patients underwent isolated AVR with the Perceval bioprosthesis, 89 patients had associated surgery and 23 patients underwent redo operations. The mean age was 77.7 ± 5 years, 139 patients were female (46%) and the mean logistic EuroSCORE was 13.2 ± 11%. At baseline, 8 patients had already an implanted pacemaker. Postoperatively, 27 patients (10.5%) required new PPM implantation due to complete atrioventricular block. On univariate analysis, age (PPM vs no-PPM group: 80 ± 5 vs 77 ± 5 years, P = 0.009) and preoperative presence of right bundle branch block (RBBB) [overall n = 20 (7.8%); PPM vs no-PPM group: 9 vs 11 (33 vs 4.8%); P < 0.001] were identified as independent predictors of postoperative conduction disorders, but only pre-existing RBBB persisted on multivariate analysis (odds ratio 11.3-C-statistic 0.74, error estimate 0.064, confidence interval 0.672-0.801; P = 0.0002). Among patients undergoing sutureless AVR, the rate of PPM implantation was high. CONCLUSIONS The analysis of the data collected made it possible to identify preoperatively a subset of patients undergoing sutureless AVR at higher risk of postoperative atrioventricular block. Additional surgical precautions should be implemented to prevent the occurrence of conduction disorders after sutureless AVR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perceval Sutureless Valve – are Sutureless Valves Here?

With the advent of transcatheter aortic valve implantation (TAVI) techniques, a renewed interest has developed in sutureless aortic valve concepts in the last decade. The main feature of sutureless aortic valve implantation is the speed of insertion, thus making implantation easier for the surgeon. As a result, cross clamp times and myocardial ischemia may be reduced. The combined procedures (C...

متن کامل

Sutureless Perceval Aortic Valve Versus Conventional Stented Bioprostheses: Meta‐Analysis of Postoperative and Midterm Results in Isolated Aortic Valve Replacement

BACKGROUND Aortic stenosis is the most common valvular disease and has a dismal prognosis without surgical treatment. The aim of this meta-analysis was to quantitatively assess the comparative effectiveness of the Perceval (LivaNova) valve versus conventional aortic bioprostheses. METHODS AND RESULTS A total of 6 comparative studies were identified, including 639 and 760 patients who underwen...

متن کامل

Early Clinical Results of Perceval Sutureless Aortic Valve in 139 Patients: Freeman Experience

OBJECTIVE The aim of this retrospective study is to evaluate the safety and performance of the Perceval sutureless valve in patients undergoing aortic valve replacement. We report the 30-day clinical outcomes of 139 patients. METHODS From January 2014 to December 2016, 139 patients underwent sutureless aortic valve replacement. Their operation notes, National Adult Cardiac Surgery Database an...

متن کامل

Aortic valve replacement in elderly with small aortic root and low body surface area; the Perceval S valve and its impact in effective orifice area

BACKGROUND The aim of this study is to see how the sutureless, stentless, Perceval S aortic valves behave when implanted in elderly patients with small aortic root and the comparison with a second group of patients with similar characteristics where a conventional stented bioprosthesis was implanted. This is a prospective randomized institutional study. METHODS Our material is composed from 2...

متن کامل

Aortic Root Enlargement or Sutureless Valve Implantation?

Aortic valve replacement (AVR) in patients with a small aortic annulus is a challenging issue. The importance of prosthesis-patient mismatch (PPM) post aortic valve replacement (AVR) is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively a...