Human tissue valves in aortic position: determinants of reoperation and valve regurgitation.

نویسندگان

  • T P Willems
  • J J Takkenberg
  • E W Steyerberg
  • V E Kleyburg-Linkers
  • J R Roelandt
  • E Bos
  • L A van Herwerden
چکیده

BACKGROUND Human tissue valves for aortic valve replacement have a limited durability that is influenced by interrelated determinants. Hierarchical linear modeling was used to analyze the relation between these determinants of durability and valve regurgitation measured by serial echocardiography. METHODS AND RESULTS In adult patients, 218 cryopreserved aortic allografts were implanted with the subcoronary (85) or the root replacement technique (133), and 81 patients had root replacement with a pulmonary autograft. Mean follow-up was 4.2 years (SD 2.7; range, 0 to 10.5). Patient age, operator experience with subcoronary implantation, and allograft diameter were independent predictors for reoperation. With repeated color Doppler echocardiography, the severity of aortic regurgitation was assessed by the jet length method and the jet diameter ratio. Multilevel hierarchical linear modeling was used to estimate initial aortic regurgitation (intercept), its change over time (slope), and the effect of 11 potential determinants of durability on aortic regurgitation. With the jet length method, the intercept was 0.94 grade and the slope was 0.11 grade per year. With the jet diameter ratio, the intercept was 0.34 and the annual increase was 0.01. Subcoronary implanted valves had more initial aortic regurgitation, but progression of aortic valve regurgitation did not differ from root replacement. At midterm follow-up, recipient age <40 years was the only independent predictor of aortic regurgitation. CONCLUSIONS Subcoronary implantation has a learning curve, resulting in more initial aortic regurgitation and early reoperation compared with root replacement. In both techniques, progression of aortic regurgitation over time is small but accelerated in young adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valve dysfunction of the cloth-covered Starr-Edwards ball valve.

BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...

متن کامل

Stentless aortic valve replacement: an update

Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 103 11  شماره 

صفحات  -

تاریخ انتشار 2001