Implementation of a Novel 8-Ch Phase-Array Transmit/Receive Head Coil with RF Interface for Parallel Transmission on 3T

نویسندگان

  • R. Xue
  • H. Zhu
  • H. Ma
  • Y. Li
  • Y. Zhuo
چکیده

INTRODUCTION High and/or ultra-high field (UHF) whole-body MR spectrometer emerges as a cutting-edge new millennium technology [1-2]. With significantly higher signal to noise ratio (SNR) and higher resolution, it obtains increased abilities in detecting human microscopic structures comparable with conventional histology, which were previously unseen in lower field. It also enables the observation and analysis of metabolic pathways and functions in living tissues with dramatically abundant details. However, UHF technology also prompts problems related with high frequency RF signals. At ultra high field, due to the sample’s “dielectric resonance effect”, the transmit RF signal generates inhomogenous B1 distribution [3]. High resonance frequency also renders high energy deposition (high SAR values) in human subjects. One feasible solution for these issues is to implement multi-channel transmit/receive (Tx/Rx) RF coils in ultra high field, incorporated with parallel imaging techniques [1-4]. In this project, we have developed a novel 8-channel phase-array Tx/Rx head coil on a Siemens 3T Tim Trio system for parallel transmission, and examined the property of this Tx/Rx coil to expect higher SNR for visual stimulation fMRI experiments. METHODS A novel 8-channel phase-array Tx/Rx head coil with related RF interface was constructed as shown in Fig.1 (a) and (b). The coil was made of polycarbonate and took a cylindrical mechanical structure with a slight bump in the nasal region. The coil inner diameter was 21cm with 26.5 cm in length and 5mm in thickness. The diameter of the coil was slightly less than the standard 12-channel head coil in order to achieve better SNR. A rectangular window of size 116mmx74mm was opened in the upper part of the coil to ensure an unblocked visual field for cognitive science studies. Eight relatively even-spaced rectangular surface loops were divided into 2 clusters, each consisting of 4 loops. The adjacent phase-array loops were decoupled via properly overlapped regions and/or shared common capacitors [5]. For the opposite surface loops, the coupling effect was neglected due to the geometric distance and low-impedance preamplifier decoupling [6]. All the elements were tuned to 123.2MHz and matched to 45-57 ohms with a 7300ml water phantom loading. Network analyzer output was as follows: S11 less than -16db for each channel, S21 decoupling less than -12db between adjacent and opposite loops. Parallel transmission pathway was implemented via a 1-to-8 power splitter and 8 T/R switches, as shown in Fig.1(b) and (c). Phase shifting was achieved using Belden RF coaxial cables with distinct length, and signal losses along the cables between the coil and preamplifiers were less than 0.3 dB. In this setup, RF shimming was achieved by applying linear phase shifters to upper and lower clusters of loops and there was a 180o phase shift of adjacent loops in two clusters. Using special mode-scanning excitation patterns via cable phase shifters and/or RF attenuators, we expect to get region-specific B1 distribution, which may yield higher image SNR in regions of interest [7,8]. In the case of homogenous RF shimming, the global and local SAR distribution of this Tx/Rx coil seemed to function similarly as a TEM birdcage coil. We had set the global SAR control to a conservative value in conformity with the existing FDA standard. The local SAR distribution was monitored via the temperature measurment taken by a Fluke T125 thermal imager through long-time, high power-level, parallel transmission experiments on both a water phantom and a piece of 5kg pork meat. The standard GRE, T1-MPRAGE, T2-TSE and BOLD-EPI sequences were employed to examine properties of the Tx/Rx coil, in compliance with the SAR limitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved B1+ field using a 16-channel Transmit Head Array and an 8-channel pTx System at 7T

INTRODUCTION At 7T, transmit coil arrays using parallel transmit (pTx) [1] systems enable techniques to substantially improve B1 transmit fields. Receive coil arrays offer enhanced sensitivity and parallel imaging performance. However, significant challenges in ultra high field systems are still remaining for the design and implementation of RFcoils for dedicated transmit channels and their int...

متن کامل

32 Channel Coil Array for Parallel RF Transmission

Introduction: As part of a study that investigates a substantially distributed multi-channel parallel transmit approach, head-size 32-element transmit/receive arrays were developed. The specific goal of the coil development is to facilitate reduction of RF power dissipation in the imaged object / the coil structure, and to facilitate B1 shimming / accelerated parallel excitation for an arbitrar...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Transmit Arrays and Circuitry

For body dimensions at 3T and head dimensions at 7T and above the RF wavelength in dielectric tissue is comparable or smaller than the dimensions of the human anatomy. This in turn leads to RF phase related traveling time differences, prominent wave behavior and the potential for a significant difference between transmit B1 + and receive B1 fields [5-10]. It is possible to correct some of the r...

متن کامل

A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla.

A novel geometrically adjustable transceiver array system is presented. A key feature of the geometrically adjustable array was the introduction of decoupling capacitors that allow for automatic change in capacitance dependent on neighboring resonant element distance. The 16-element head array version of such an adjustable coil based on transmission line technology was compared to fixed geometr...