Implantable Cardioverter-Defibrillator Lead Extraction by Conventional Traction and Counter-Traction Technique

نویسندگان

  • Jong Sung Park
  • Hui-Nam Pak
  • Moon-Hyoung Lee
  • Sung Soon Kim
  • Boyoung Joung
چکیده

A 46-year-old man presented to our institution with inappropriate implantable cardioverter-defibrillator (ICD) shock delivery. The ICD (single chamber, dual shock coils) was implanted for sustained monomorphic ventricular tachycardia with unstable hemodynamics and underlying systolic left ventricular dysfunction. ICD interrogation revealed recurrent episodes of ICD shock due to noise sensing and increased impedance of right ventricular (RV)-lead. With the impression of lead fracture, ICD lead extraction was performed. The fractured ICD lead was completely removed by traction of locking stylet and counter-traction of polypropylene dilator sheath. A new lead was inserted and the patient was discharged without complications after 2 days. To our knowledge, this is the first report on ICD lead extraction by conventional traction and counter-traction technique in Korea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful extraction of an implantable cardioverter-defibrillator lead in a patient with pocket infection via the femoral approach with a basket snare

A 27-year-old man was admitted to our institution with implantable cardioverter-defibrillator (ICD) pocket infection. The ICD (single chamber, dual shock coils) was implanted for the prevention of aborted sudden cardiac death due to idiopathic ventricular fibrillation. Because we could not use locking stylet and countertraction manuever, baseket snare with metal wire should be hanged at the max...

متن کامل

Removal of the broken part of implantable cardioverter-defibrillator's electrode causing pulmonary embolism via femoral vein.

A 66-year-old patient with idiopathic dilated cardiomyopathy underwent transvenous extraction of an implantable cardioverter-defibrillator. The distal part of the electrode was broken during manual traction through the left subclavian vein. In the present case, we showed a rare complication of transvenous lead extraction and its management.

متن کامل

A hybrid ICD extraction approach using laser and transfemoral extraction technique.

Indications for pacemaker and implantable cardioverter defibrillator (ICD) implantations are rapidly expanding. Hence, device-related complications have increased the need for lead extraction. Lead extractions are performed percutaneously or by open surgery. We present a patient with isolated left ventricular noncompaction cardiomyopathy suffering from ICD pulse generator pocket and lead infect...

متن کامل

Forces Applied during Transvenous Implantable Cardioverter Defibrillator Lead Removal

METHODS 17 physicians, experienced in transvenous lead removal, performed a lead extraction manoeuvre of an ICD lead on a torso phantom. They were advised to stop traction only when further traction would be considered as harmful to the patient or when--based on their experience--a change in the extraction strategy was indicated. Traction forces were recorded with a digital precision gauge. R...

متن کامل

A single-centre experience of over one thousand lead extractions

AIMS The aim of the study was to present a single-centre experience of pacemaker and implantable cardioverter defibrillator (ICD) lead extraction using different methods, mainly laser-assisted extraction. METHODS AND RESULTS Data from 1032 leads and 647 procedures were gathered. A step-by-step approach using different techniques while performing an ongoing risk-benefit analysis was used. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2010