Endocarditis risk of the USCI PDA umbrella for transcatheter closure of patent ductus arteriosus.
نویسندگان
چکیده
BACKGROUND The USCI PDA Umbrella is a device to close patent ductus arteriosus (PDA) by a transcatheter technique. Human clinical trials have shown excellent efficacy in reducing or eliminating the PDA shunt, but concerns remain about the risk of infection with this device. The purpose of this study was to evaluate the risk of infection using an animal model. METHODS AND RESULTS Susceptibility to developing endocarditis was tested by injecting a single intravenous dose of group L streptococcus. Ten piglets with a closed ductus served as controls. Two of these developed valvular vegetations. PDA was produced in 19 animals by balloon dilation of the ductus. Seven of 7 animals with PDA at the time of bacterial injection developed endarteritis of the ductus and valvular vegetations. A PDA Umbrella was placed in the remaining 12 animals, and bacteria were injected 2 weeks after device implantation. Infection was evident in the PDA Umbrella only in the single animal in which the Umbrella had embolized and been left in the left pulmonary artery. Three of the remaining 11 piglets had a significant residual leak, and all developed infection in the ductus and an additional valve. Similar to the control group, none of the animals with complete (n = 8) or nearly complete (n = 2) closure of the ductus by the PDA Umbrella had infection in or around the ductus, and only 1 had a valvular vegetation. CONCLUSIONS In this animal model, presence of a significant PDA shunt (with or without a PDA Umbrella present) results in significantly increased susceptibility to endarteritis and endocarditis. The PDA Umbrella device does not appear to be susceptible to direct infection as early as 2 weeks after implantation if it is properly located in the ductus arteriosus. Animals with no shunt or a trivial shunt are no more susceptible to developing endocarditis 2 weeks after PDA Umbrella implantation than are controls.
منابع مشابه
Transcatheter Closure of Patent Ductus Arteriosus
Background The USCI PDA Umbrella is a device to close patent ductus arteriosus (PDA) by a transcatheter technique. Human clinical trials have shown excellent efficacy in reducing or eliminating the PDA shunt, but concerns remain about the risk of infection with this device. The purpose of this study was to evaluate the risk of infection using an animal model. Methods and Results Susceptibility ...
متن کاملComplications after Transcatheter Closure of Patent Ductus Arteriosus
To evaluate the short- and mid-term results and complications ensuing the transcatheter closure of patent ductus arteriosus (PDA). Between October 1999 and December 2005, 117 patients (34 males and 83 females) underwent attempted percutaneous closure of PDA with a minimum diameter of more than 3 mm. Follow-up evaluations were conducted at 1 day and 1, 3, 6, 12 months after the performance of th...
متن کاملTo close or not to close: the very small patent ductus arteriosus.
Patent ductus arteriosus (PDA) accounts for approximately 10% of all congenital heart diseases, with an incidence of at least 2-4 per 1000 term births. Closure of the large, hemodynamically significant PDA is established as the standard of care, and can be performed safely and effectively using either surgical or transcatheter methods. The appropriate management of the very small, hemodynamical...
متن کاملIntravenous Paracetamol and Patent Ductus Arteriosus Closure
Background: Standard medical treatments for patent ductus arteriosus (PDA) closure are, including indomethacin/ibuprofen and surgical ligation. Nowadays, a new strategy to close PDA is the use of paracetamol. The present study aimed to describe the use of intravenous (IV) paracetamol for PDA closure in neonates who present a contraindication to ibuprofen or ibuprofen failure with no possibility...
متن کاملThe Effect of Oral Ibuprofen on Closure of Patent Ductus Arteriosus in Term Neonates: A Clinical Trial Study
Background The function of ductus arteriosus closes within a few minutes to a few days after birth in term neonates. In some cases, the duct remains open after birth, a condition which is called patent ductus arteriosus (PDA). PDA is associated with high rates of neonatal mortality and morbidity. The present study aims to evaluate the effect of...