The potential for catheter microbial contamination from a needleless connector.

نویسندگان

  • J D Brown
  • H A Moss
  • T S Elliott
چکیده

Needleless connectors have been widely introduced into clinical practice to allow the connection of syringes and luers to peripheral and central vascular catheters. The potential for microbial contamination of catheters via these devices is currently unclear. A recently introduced connector, the 'Connecta Clave', was assessed by various in-vitro methods. The 'Connecta Clave' is specifically devised to separate external components from the fluid pathway. The compression seals of 50 devices were contaminated with 1 x 10(4) cfu Staphylococcus epidermidis, disinfected with isopropanol, and fluid passed through. Only one device allowed organisms to pass through, despite this challenge, representing a contamination rate of 2%. In comparison, when 50 connectors were challenged with 20 cfu of S. epidermidis, no organisms passed through the device during use. In the clinical situation, after manipulation, < 16 cfu of skin organisms were found associated with the compression seal of the devices. It is, therefore, likely that the contamination rates in clinical practice will be extremely low. Three methods of disinfecting the compression seals and associated rims were also evaluated. A combination of alcohol chlorhexidine spray, followed by a 70% isopropanol swab, resulted in the most efficacious disinfection. The isopropanol swabs produced an adequate disinfection rate. The overall results suggest that by use of specially designed connectors, not only are needlestick injuries reduced, but the likelihood of microbial contamination of catheters via the internal route may also be diminished.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disinfection of Needleless Connector Hubs: Clinical Evidence Systematic Review

Background. Needleless connectors (NC) are used on virtually all intravascular devices, providing an easy access point for infusion connection. Colonization of NC is considered the cause of 50% of postinsertion catheter-related infections. Breaks in aseptic technique, from failure to disinfect, result in contamination and subsequent biofilm formation within NC and catheters increasing the poten...

متن کامل

Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve.

BACKGROUND Needleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introductio...

متن کامل

Alcohol Caps or Alcohol Swabs With and Without Chlorhexidine: An In Vitro Study of 648 Episodes of Intravenous Device Needleless Connector Decontamination.

The incidence of central venous access device (CVAD)–associated bloodstream infection (CABSI) has been reported to be as high as 21%. Inadequate needleless connector decontamination can result in microbial contamination of the CVAD internal lumen, resulting in device colonization and CABSI. Guidelines vary in recommendations for antiseptic type and duration of application to needleless connecto...

متن کامل

In vitro studies of a novel antimicrobial luer-activated needleless connector for prevention of catheter-related bloodstream infection.

BACKGROUND We report in vitro studies of a commercially available novel antimicrobial Luer-activated connector with the inner surface coated with nanoparticle-silver to prevent contaminants from forming biofilm and causing catheter-related bloodstream infection. METHODS Sterile control nonmedicated connectors and antimicrobial connectors were filled with approximately 1 x 10(5) cfu/mL of Stap...

متن کامل

Disinfection of needleless catheter connectors and access ports with alcohol may not prevent microbial entry: the promise of a novel antiseptic-barrier cap.

BACKGROUND Needleless valve connectors for vascular catheters are widely used throughout the United States because they reduce the risk of biohazardous injuries from needlesticks and exposure to bloodborne pathogens, such as human immunodeficiency virus and hepatitis C virus. Patients with long-term central venous catheters are at significant risk of acquiring catheter-related bloodstream infec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hospital infection

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 1997