Automatic classification of HITS into artifacts or solid or gaseous emboli by a wavelet representation combined with dual-gate TCD.

نویسندگان

  • G Devuyst
  • G A Darbellay
  • J M Vesin
  • V Kemény
  • M Ritter
  • D W Droste
  • C Molina
  • J Serena
  • R Sztajzel
  • P Ruchat
  • C Lucchesi
  • G Dietler
  • E B Ringelstein
  • P A Despland
  • J Bogousslavsky
چکیده

BACKGROUND AND PURPOSE Transcranial Doppler (TCD) can detect high-intensity transient signals (HITS) in the cerebral circulation. HITS may correspond to artifacts or solid or gaseous emboli. The aim of this study was to develop an offline automated Doppler system allowing the classification of HITS. METHODS We studied 600 HITS in vivo, including 200 artifacts from normal subjects, 200 solid emboli from patients with symptomatic internal carotid artery stenosis, and 200 gaseous emboli in stroke patients with patent foramen ovale. The study was 2-fold, each part involving 300 HITS (100 of each type). The first 300 HITS (learning set) were used to construct an automated classification algorithm. The remaining 300 HITS (validation set) were used to check the validity of this algorithm. To classify HITS, we combined dual-gate TCD with a wavelet representation and compared it with the current "gold standard," the human experts. RESULTS A combination of the peak frequency of HITS and the time delay makes it possible to separate artifacts from emboli. On the validation set, we achieved a sensitivity of 97%, a specificity of 98%, a positive predictive value (PPV) of 99%, and a negative predictive value (NPV) of 94%. To distinguish between solid and gaseous emboli, where positive refers now to the solid emboli, we used the peak frequency, the relative power, and the envelope symmetry of HITS. On the validation set, we achieved a sensitivity of 89%, a specificity of 86%, a conditional PPV of 89%, and a conditional NPV of 89%. CONCLUSIONS An automated wavelet representation combined with dual-gate TCD can reliably reject artifacts from emboli. From a clinical standpoint, however, this approach has only a fair accuracy in differentiating between solid and gaseous emboli.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شناسایی میکرو آمبولی مغزی در سیگنال داپلر از روی ویژگی های غیر خطی

Abstract: An embolus is a blood clot, a fat globule or gas bubbles that may be freely circulating in bloodstream can stop the blood flow and lead to ischemia. In real time assessment of blood flow by Trans Cranial Doppler (TCD) method, travelling solid or gaseous micro emboli in the bloodstream by passing across the assessment area, causes a short time signal with high intensity. While TCD reco...

متن کامل

Silent Cerebral Microembolism during Coronary Artery Bypass Graft Surgery

A 62 year-old man with known coronary artery disease underwent a three-vessel CABG after a positive exercise tolerance test revealed reversible ischemic changes. Transcranial Doppler ultrasonography (TCD) and transesophageal monitoring (TEE) were used intraoperatively for monitoring of highintensity transient signals (HITS), representing both gaseous and particulate cerebral emboli. Non-pulsati...

متن کامل

Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system.

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can reliably detect both gaseous and solid cerebral emboli. However, conventional equipment is unable to discriminate between gaseous and solid emboli. This is a major limitation in situations in which the 2 coexist, because they may have very different clinical relevance. Recently, a novel Embo-Dop system, using insonation at 2 ultrasound ...

متن کامل

Representation of a nanoscale heterostructure dual material gate JL-FET with NDR characteristics

In this paper, we propose a new heterostructure dual material gate junctionless field-effect transistor (H-DMG-JLFET), with negative differential resistance (NDR) characteristic. The drain and channel material are silicon and source material is germanium. The gate electrode near the source is larger. A dual gate material technique is used to achieve upward band bending in order to access n-i-p-...

متن کامل

Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.

BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 32 12  شماره 

صفحات  -

تاریخ انتشار 2001