Development of image quality assurance measures of the ExacTrac localization system using commercially available image evaluation software and hardware for image‐guided radiotherapy

نویسندگان

  • Dennis N. Stanley
  • Nikos Papanikolaou
  • Alonso N. Gutierrez
چکیده

Quality assurance (QA) of the image quality for image-guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, a methodology was developed to assess and evaluate the constancy of the high-contrast spatial resolution, dose, energy, contrast, and geometrical accuracy of the BrainLAB ExacTrac system. An in-house fixation device was constructed to hold the QCkV-1 phantom firmly and reproducibly against the face of the flat panel detectors. Two image sets per detector were acquired using ExacTrac preset console settings over a period of three months. The image sets were analyzed in PIPSpro and the following metrics were recorded: high-contrast spatial resolution (f30, f40, f50 (lp/mm)), noise, and contrast-to-noise ratio. Geometrical image accu- racy was evaluated by assessing the length between to predetermined points of the QCkV-1 phantom. Dose and kVp were recorded using the Unfors RaySafe Xi R/F Detector. The kVp and dose were evaluated for the following: Cranial Standard (CS) (80 kV,80 mA,80 ms), Thorax Standard (TS) (120 kV,160 mA,160 ms), Abdomen Standard (AS) (120 kV,160 mA,130 ms), and Pelvis Standard (PS) (120 kV,160 mA,160 ms). With regard to high-contrast spatial resolution, the mean values of the f30 (lp/mm), f40 (lp/mm) and f50 (lp/mm) for the left detector were 1.39 ± 0.04, 1.24 ± 0.05, and 1.09 ± 0.04, respectively, while for the right detector they were 1.38 ± 0.04, 1.22 ± 0.05, and 1.09 ± 0.05, respectively. Mean CNRs for the left and right detectors were 148 ± 3 and 143 ± 4, respectively. For geometrical accuracy, both detectors had a measured image length of the QCkV-1 of 57.9 ± 0.5 mm. The left detector showed dose measurements of 20.4 ± 0.2 μGy (CS), 191.8 ± 0.7 μGy (TS), 154.2 ± 0.7 μGy (AS), and 192.2 ± 0.6 μGy (PS), while the right detector showed 20.3 ± 0.3 μGy (CS), 189.7 ± 0.8 μGy (TS), 151.0 ± 0.7 μGy (AS), and 189.7 ± 0.8 μGy (PS), respectively. For X-ray energy, the left detector (right X-ray tube) had mean kVp readings of 81.6 ± 0.5 (CS), 122.5 ± 0.5 (TS), 122.0 ± 0.8 (AS), and 122.1 ± 0.7 (PS), and the right detector (left X-ray tube) had 81.6 ± 0.5 (CS), 120.8 ± 0.5 (TS), 120.9 ± 0.6 (AS), and 121.3 ± 0.7 (PS). Run charts were created so that each parameter could be tracked over time and the constancy of the system could be monitored. A methodology was developed to assess the basic image quality parameters recommended by TG-142 for the ExacTrac system. The ExacTrac system shows a consistent dose, kVp, high-contrast spatial resolution, CNR, and geometrical accuracy for each detector over the evaluated timeframe. 

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Health technology assessment of image-guided radiotherapy (IGRT): A systematic review of current evidence

Background: Image-guided radiotherapy used multiple imaging during the radiation therapy course to improve the precision and accuracy of health care provider's treatment. Objectives: This study aims to assess the safety, effectiveness and economic aspects of image-guided radiation therapy for decision-making about this technology in Iran. Methods: In this study, the most important med...

متن کامل

Evaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System

Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: ...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

Calculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model

Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...

متن کامل

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014