Preserved endothelium-dependent vasodilation in coronary segments previously treated with balloon angioplasty and intracoronary irradiation.

نویسندگان

  • M Sabaté
  • I P Kay
  • W J van Der Giessen
  • A Cequier
  • J M Ligthart
  • J A Gómez-Hospital
  • S G Carlier
  • V L Coen
  • J P Marijnissen
  • A J Wardeh
  • P C Levendag
  • P W Serruys
چکیده

BACKGROUND Abnormal endothelium-dependent coronary vasomotion has been reported after balloon angioplasty (BA), as well as after intracoronary radiation. However, the long-term effect on coronary vasomotion is not known. The aim of this study was to evaluate the long-term vasomotion of coronary segments treated with BA and brachytherapy. METHODS AND RESULTS Patients with single de novo lesions treated either with BA followed by intracoronary beta-irradiation (according to the Beta Energy Restenosis Trial-1.5) or with BA alone were eligible. Of these groups, those patients in stable condition who returned for 6-month angiographic follow-up formed the study population (n=19, irradiated group and n=11, control group). Endothelium-dependent coronary vasomotion was assessed by selective infusion of serial doses of acetylcholine (ACh) proximally to the treated area. Mean luminal diameter was calculated by quantitative coronary angiography both in the treated area and in distal segments. Endothelial dysfunction was defined as a vasoconstriction after the maximal dose of ACh (10(-6) mol/L). Seventeen irradiated segments (89.5%) demonstrated normal endothelial function. In contrast, 10 distal nonirradiated segments (53%) and 5 control segments (45%) demonstrated endothelium-dependent vasoconstriction (-19+/-17% and -9.0+/-5%, respectively). Mean percentage of change in mean luminal diameter after ACh was significantly higher in irradiated segments (P=0.01). CONCLUSIONS Endothelium-dependent vasomotion of coronary segments treated with BA followed by beta-radiation is restored in the majority of stable patients at 6-month follow-up. This functional response appeared to be better than those documented both in the distal segments and in segments treated with BA alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pravastatin and endothelium dependent vasomotion after coronary angioplasty: the PREFACE trial.

OBJECTIVE To test the hypothesis that the 3-hydroxy-3-methylglutaryl coenzyme-A reductase inhibitor pravastatin ameliorates endothelium mediated responses of dilated coronary segments: the PREFACE (pravastatin related effects following angioplasty on coronary endothelium) trial. DESIGN A double blind, randomised, placebo controlled, multicentre study. SETTING Four hospitals in the Netherlan...

متن کامل

Serotonin After Injury by Coronary Angioplasty

Background. Atherosclerotic stenoses that have exaggerated vasomotor responses are especially prone to restenosis after coronary angioplasty. Experimental studies show that vasomotor responses in normal vessels are altered by acute mechanical injury, an alteration that in part reflects changes in the functional characteristics of endothelium that has regenerated after injury. Methods and Result...

متن کامل

Time course of endothelium-dependent and -independent coronary vasomotor response to coronary balloons and stents. Comparison of plain and drug-eluting balloons and stents.

OBJECTIVES This study sought to determine the time dependency of the endothelium-dependent and -independent vascular responses after percutaneous coronary intervention (PCI) with drug-eluting (DEB) or plain balloons, bare-metal (BMS), and drug-eluting (DES) stents, or controls. BACKGROUND Long-term endothelial dysfunction after DES implantation is associated with delayed healing and late thro...

متن کامل

Trauma induced by nontraumatic coronary devices and its impact on vascular reactivity and morphology.

This study evaluated the impact of low-pressure balloon devices on coronary morphology and function. An active coronary perfusion catheter (2.5-mm balloon diameter, inflation with 1 bar for 30 min) was placed in the left anterior descending coronary artery of 12 German landrace pigs under general anesthesia. After 3 mo, coronary segments with balloon contact were compared with control segments ...

متن کامل

Intracoronary Thrombus Formation Causes Focal Vasoconstriction of Epicardial Arteries

Background. Experimental studies have demonstrated that intracoronary platelet aggregation and thrombus formation may induce marked vasoconstriction of epicardial arteries with endothelial injury. Methods and Results. To examine the effects of intracoronary thrombus formation on coronary vasomotor tone of human epicardial arteries in vivo, we studied 15 patients who developed intracoronary thro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 100 15  شماره 

صفحات  -

تاریخ انتشار 1999