Position Control of Tendon-Driven Fingers

نویسندگان

  • Muhammad E. Abdallah
  • Robert Platt
  • Brian Hargrave
  • Frank Permenter
چکیده

Conventionally, tendon-driven manipulators implement some force control scheme based on tension feedback. This feedback allows the system to ensure that the tendons are maintained taut with proper levels of tensioning at all times. Occasionally, whether it is due to the lack of tension feedback or the inability to implement sufficiently high stiffnesses, a position control scheme is needed. This work compares three position controllers for tendon-driven manipulators. A new controller is introduced that achieves the best overall performance with regards to speed, accuracy, and transient behavior. To compensate for the lack of tension feedback, the controller nominally maintains the internal tension on the tendons by implementing a two-tier architecture with a range-space constraint. These control laws are validated experimentally on the Robonaut-2 humanoid hand.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Torque control of underactuated tendon-driven fingers

Given an underactuated tendon-driven finger, the finger posture is underdetermined and can move freely (“flop”) in a region of slack tendons. This work shows that such an underactuated finger can be operated in tendon force control (rather than position control) with effective performance. The force control eliminates the indeterminate slack while commanding a parameterized space of desired tor...

متن کامل

Decoupled torque control of tendon-driven fingers with tension management

To facilitate human assembly tasks, Robonaut 2 is equipped with a dexterous, compact hand featuring fingers driven remotely by tendons. This work outlines the force-control strategy for the fingers, which are actuated by an “n +1” tendon arrangement. Existing tendon-driven fingers have applied force control through independent tension controllers on each tendon, in other words, in the tendon sp...

متن کامل

Optimizing the Topology of Tendon-Driven Fingers: Rationale, Predictions and Implementation

Tendon-driven mechanisms in general, and tendon-driven fingers in particular, are ubiquitous in nature, and are an important class of bio-inspired mechatronic systems. However, the mechanical complexity of tendon-driven systems has hindered our understanding of biological systems, and the optimization of the design, performance, control, and construction of mechatronic systems. Here we apply ou...

متن کامل

Publications of Charles W. Wampler Edited Books

Decoupled torque control of tendon-driven fingers with tension management, " Int. Numerically intersecting algebraic varieties via witness sets, " Applied Math.

متن کامل

Effects of Non-Steroidal Anti-Inflammatory Drugs onFlexor Tendon Rehabilitation after Repair

  Background: Peritendinous adhesions after repairing an injury to the digital flexor tendons are a major problem in hand surgery. Non-steroidal anti-inflammatory drug therapy may affect tendon healing and the development of peritendinous adhesions. The aim of this study was to evaluate ibuprofen effect in patients function after flexor tendon surgical repair.   Method: Thirty-five patients, wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011