Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography.

نویسندگان

  • Shahab Noori
  • Benazir Drabu
  • Sadaf Soleymani
  • Istvan Seri
چکیده

OBJECTIVE Electrical velocimetry (EV) is a non-invasive method of continuous left cardiac output monitoring based on measurement of thoracic electrical bioimpedance. The objective was to validate EV by investigating the agreement in cardiac output measurements performed by EV and echocardiography. DESIGN In this prospective observational study, left ventricular output (LVO) was simultaneously measured by EV (LVO(ev)) using Aesculon and by echocardiography (LVO(echo)) in healthy term neonates during the first 2 postnatal days. To determine the agreement between the two methods, we calculated the bias (mean difference) and precision (1.96×SD of the difference). As LVO(echo) has its own limitations, the authors also calculated the 'true precision' of EV adjusted for echocardiography as the reference method. RESULTS The authors performed 115 paired measurements in 20 neonates. LVO(ev) and LVO(echo) were similar (534±105 vs 538±105 ml/min, p=0.7). The bias and precision of EV were -4 and 234 ml/min, respectively. The authors found the true precision of EV to be similar to the precision of echocardiography (31.6% vs 30%, respectively). There was no difference in bias and precision between the measurements obtained in patients with or without a haemodynamically significant patent ductus arteriosus. CONCLUSIONS EV is as accurate in measuring LVO as echocardiography and the variation in the agreement between EV and echocardiography among the individual subjects reflects the limitations of both techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

متن کامل

Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study

INTRODUCTION Electrical velocimetry (EV) is a type of impedance cardiography, and is a non-invasive and continuously applicable method of cardiac output monitoring. Transthoracic echocardiography (TTE) is non-invasive but discontinuous. METHODS We compared EV with TTE in pediatric intensive care patients in a prospective single-center observational study. Simultaneous, coupled, left ventricul...

متن کامل

Non-Invasive Cardiac Output Measurement in Low and Very Low Birth Weight Infants: A Method Comparison

BACKGROUND Cardiac output (CO) measurement in low (LBW) and very low (VLBW) birth weight infants is difficult. Hitherto, sporadical transthoracic echocardiography (TTE) is the only non-invasive measurement method. Electrical velocimetry (EV) has been evaluated as an alternative in normal weight newborns. OBJECTIVES The study was designed to evaluate if EV could be interchangeable with TTE eve...

متن کامل

Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.

BACKGROUND Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophageal...

متن کامل

Electrical velocimetry for measuring cardiac output in children with congenital heart disease.

BACKGROUND The purpose of this study was to evaluate the agreement of cardiac output measurements obtained by electrical velocimetry (CO(EV)) and those that derived from the direct Fick-oxygen principle (CO(F)) in infants and children with congenital heart defects. METHODS Simultaneous measurements of CO(EV) and CO(F) were compared in 32 paediatric patients, aged 11 days to 17.8 yr, undergoin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 97 5  شماره 

صفحات  -

تاریخ انتشار 2012