Experimental and modeling study of thermal exposure of a self-contained breathing apparatus (SCBA).
نویسندگان
چکیده
An experimental apparatus designed to study firefighter safety equipment exposed to a thermal environment was developed. The apparatus consisted of an elevated temperature flow loop with the ability to heat the air stream up to 200°C. The thermal and flow conditions at the test section were characterized using thermocouples and bi-directional probes. The safety equipment examined in this study was a self-contained breathing apparatus (SCBA), including a facepiece and an air cylinder. The SCBA facepiece was placed on a mannequin headform and coupled to a breathing simulator that was programmed with a prescribed breathing pattern. The entire SCBA assembly was placed in the test section of the flow loop for these thermal exposure experiments. Three air stream temperatures, 100°C, 150°C, and 200°C, were used with the average air speed at the test section set at 1.4m/s and thermal exposure durations up to 1200 s. Measurements were made using type-K bare-bead thermocouples located in the mannequin's mouth and on the outer surface of the SCBA cylinder. The experimental results indicated that increasing the thermal exposure severity and duration increased the breathing air temperatures supplied by the SCBA. Temperatures of breathing air from the SCBA cylinder in excess of 60°C were observed over the course of the thermal exposure conditions used in most of the experiments. A mathematical model for transient heat transfer was developed to complement the thermal exposure experimental study. The model took into consideration forced convective heat transfer, quasi-steady heat conduction through the composite layers of the SCBA cylinder wall, the breathing pattern and action of the breathing simulator, and predicted air temperatures from the thermally exposed SCBA cylinder and temperatures at the outer surface of the SCBA cylinder. Model predictions agreed reasonably well with the experimental measurements.
منابع مشابه
Design of a self-contained breathing apparatus (SCBA) using a carbon fibre reinforced polymer and filament winding
The design of a self-contained breathing apparatus (SCBA), which is an extremely important device for firefighting on board of ships, covers not only in-service loadings, but also a proper selection of materials, manufacturing processes, as well as the specification of other construction details, such as hydrostatic test parameters, among others. The work developed and presented in this manuscr...
متن کاملEffects of self-contained breathing apparatus on ventricular function during strenuous exercise.
The purpose of this study was to investigate left-ventricular function during strenuous exercise with the self-contained breathing apparatus (SCBA). With the use of two-dimensional echocardiography, images of the left ventricle (LV) were acquired during sustained exercise (3 x 10 min) under two conditions: 1) SCBA, or 2) low resistance breathing valve. Twenty healthy men volunteered for the stu...
متن کاملEffects of helium and 40% O2 on graded exercise with self-contained breathing apparatus.
Maximal exercise performance is decreased when breathing from a self-contained breathing apparatus (SCBA), owing to a ventilatory limitation imposed by the increased expiratory resistance. To test the hypothesis that decreasing the density of the breathing gas would improve maximal exercise performance, we studied 15 men during four graded exercise tests with the SCBA. Participants breathed a d...
متن کاملThe management of heat stress for the firefighter: a review of work conducted on behalf of the Toronto Fire Service.
This report provides a summary of research conducted through a grant provided by the Workplace Safety Insurance Board of Ontario. The research was divided into two phases; first, to define safe work limits for firefighters wearing their protective clothing and working in warm environments; and, the second, to examine strategies to reduce the thermal burden and extend the operational effectivene...
متن کاملEffect of Protective Clothing and Fatigue on Functional Balance of Firefighters
Every year, more than 38,000 firefighters are injured on the fireground [1]. Among causes of moderate or severe injuries of firefighters, slips, trips, and falls are the most significant cause (28%) of firefighting injuries, followed by overexertion (23%), struck by objects (17%), exposure to detrimental environment (15%), and others (17%) [1]. A 2003 study reported that the average medical cos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Burns : journal of the International Society for Burn Injuries
دوره 41 5 شماره
صفحات -
تاریخ انتشار 2015