High-density data acquisition system and signal preprocessor for interfacing with microelectromechanical system-based biosensor arrays.

نویسندگان

  • M Rokkam
  • M R Chatni
  • A ul Haque
  • A R De Carlo
  • B F Robinson
  • P P Irazoqui
  • D M Porterfield
چکیده

Microelectromechanical system (MEMS) development has become an active area for research in over the last decade. This area has advanced rapidly in recent years due to the potential ability of MEMS devices to perform complex functions in a smaller area. There is also the prospect to develop devices that can (1) be easily manufactured, (2) offer low power consumption, and (3) reduce waste. Especially in the BioMEMS area these advantages are important in terms of applied devices for biosensing, clinical diagnostics, physiological sensing, flow cytometry, and other lab-on-a-chip applications. However, one major obstacle that has been overlooked is the interface of these microdevices with the macroworld. This is critical to enable applications and development of the technology, as currently testing and analysis of data from these devices is mostly limited to generic microprobe stations. New advancements in BioMEMS have to occur in concert with the development of data acquisition systems and signal preprocessors to fully appreciate and test these developing technologies. In this work, we present the development of a cost effective, high throughput data acquisition system (Bio-HD DAQ) and a signal preprocessor for a MEMS-based cell electrophysiology lab-on-a-Chip (CEL-C) device. The signal preprocessor consists of a printed circuit board mounted with the CEL-C device and a 64-channel filter/amplifier circuit array. The data acquisition system includes a high-density crosspoint switching matrix that connects the signal preprocessor to a 16-channel, 18 bit, and 625 kSs DAQ card. Multimodule custom software designed on LABVIEW 7.0 is used to control the DAQ system. While this version of the Bio-HD DAQ system and accompanying software are designed keeping in view the specific requirements of the CEL-C device, it is highly adaptable and, with minor modifications, can become a generic data acquisition system for MEMS development, testing, and application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of an Amperometric Biosensor using a Simple Microcontroller based Data Acquisition System

In this paper we have proposed a methodology to develop an amperometric biosensor for the analysis of glucose concentration using a simple microcontroller based data acquisition system. The work involves the development of Detachable Membrane Unit (enzyme based biomembrane) with immobilized glucose oxidase on the membrane and interfacing the same to the signal conditioning system. The current g...

متن کامل

Integrated Biosensor and Interfacing Circuits

Driven by the demand of the bioelectronics market, many biosensors need to work in parallel or in a controllable way to achieve complicated biodetections, however the limited scale, speed, cost, complex signal processing, and bulky circuit routing problems prohibit the discrete biosensor solutions (Drummond et al., 2003). Nowaday biosensor are usually integrated on the same substrate to form bi...

متن کامل

AN INTELLIGENT FAULT DIAGNOSIS APPROACH FOR GEARS AND BEARINGS BASED ON WAVELET TRANSFORM AS A PREPROCESSOR AND ARTIFICIAL NEURAL NETWORKS

In this paper, a fault diagnosis system based on discrete wavelet transform (DWT) and artificial neural networks (ANNs) is designed to diagnose different types of fault in gears and bearings. DWT is an advanced signal-processing technique for fault detection and identification. Five features of wavelet transform RMS, crest factor, kurtosis, standard deviation and skewness of discrete wavelet co...

متن کامل

Performance Study of Untrusted Relay Network Utilizing Cooperative Jammer

Abstract—In this paper, the problem of secure transmission in two-hop amplify-and-forward (AF) systems with an untrusted relay is investigated. To prevent the untrusted relay from intercepting the source message and to achieve positive secrecy rate, the destination-based cooperative jamming (DBCJ) technique is used. In this method the destination sends an intended jamming signal to the relay. T...

متن کامل

DNA Biosensor for Determination of 5-Fluorouracil based on Gold Electrode Modified with Au and Polyaniline Nanoparticles and FFT Square Wave Voltammetry

In the present study, a new biosensor for 5-Fluorouracil was described using modified goldelectrode and Fast Fourier transform square wave voltammetry (FFT SWV). Calf thymus DNAimmobilization was on a gold electrode decorated with polyaniline and gold nanoparticles. Theelectrochemical characteristics of the electrodes were investigated by cyclic voltammetry, andelectroch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 78 4  شماره 

صفحات  -

تاریخ انتشار 2007