Double-counting of intracardiac electrogram during biatrial pacing.

نویسندگان

  • Tsukasa Kobayashi
  • Toshiyuki Ishikawa
  • Shinichi Sumita
  • Youhei Yamakawa
  • Yasuo Ohkusu
  • Kohei Matsusita
  • Katsumi Matsumoto
  • Tsuyoshi Nakagawa
  • Ichirou Nakazawa
  • Yasuyuki Mochida
  • Toshiaki Ebina
  • Kazuaki Uchino
  • Kazuo Kimura
  • Satoshi Umemura
چکیده

BACKGROUND Biatrial pacing has a significant problem with memory function that misinterprets normal sinus rhythm as atrial tachyarrhythmias and in addition estimation of the atrial pacing thresholds (biatrial and uniatrial pacing thresholds) is sometimes difficult because of small P waves. METHODS AND RESULTS The intracardiac electrograms recorded by a pacemaker in 10 patients (age, 66.7+/-10.7 (SD) years) with implanted biatrial pacemakers were analyzed. Atrial sensing within the atrial refractory period after atrial pacing was counted in 6 of the 10 patients (timing of the double counting was 143+/-64 ms) when pacing failed in the left or right atrium. Atrial sensing within the atrial refractory period after atrial pacing disappeared when biatrial pacing was successfully performed. Atrial double-counts depend on interatrial conduction delay. The memory function of implanted pacemaker devices misinterpreted normal sinus rhythm as atrial tachyarrhythmias because of atrial double-counts. On the other hand, the biatrial pacing threshold was easily recognized using this phenomenon. CONCLUSIONS The memory function of pacemaker devices is unreliable because of atrial double-counting during sinus rhythm in patients with biatrial pacing. However, the biatrial pacing threshold is easily checked using this phenomenon.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of ventricular tachycardia using intracardiac electrograms: a comparison of unipolar versus bipolar waveform analysis.

Implantable antitachycardia devices suffer a high false-positive rate of delivery of therapy because current detection schemes based upon ventricular rate and rate variations are excessively sensitive at the cost of specificity. Several methods have been proposed for providing complementary information derived from morphologic analysis of intraventricular electrograms in order to increase speci...

متن کامل

Inappropriate mode switch consecutive to P-wave double counting.

We report a case of multiple inappropriate mode switches in a patient with a dual-chamber pacemaker, resulting from P-wave double counting due to a double potential on the atrial electrogram. The differential diagnosis of this rarely reported phenomenon is discussed.

متن کامل

The Bin Area Method: a computationally efficient technique for analysis of ventricular and atrial intracardiac electrograms.

Recent studies have reported a significant false positive rate in delivery of therapy by implantable antitachycardia devices utilizing detection algorithms based on sustained high rate. More selective decision schemes for the recognition of life-threatening arrhythmias have been recently proposed that use analysis of the intrinsic electrogram rather than rate alone. Morphological discrimination...

متن کامل

A time-domain analysis of intracardiac electrograms for arrhythmia detection.

The analysis of intracardiac electrogram morphology has been proposed as a complementary method for accurate discrimination between sinus rhythm (SR), supraventricular dysrhythmias, and ventricular dysrhythmias by automatic antitachycardia and cardioverter defibrillator devices. In this study, the performance of a traditional time-domain method for surface electrocardiogram interpretation--Corr...

متن کامل

Discrimination of retrograde from anterograde atrial activation using intracardiac electrogram waveform analysis.

The prevention of pacemaker-mediated tachycardias requires a safe, reliable method for distinguishing retrograde from anterograde atrial activation by dual chamber pacemakers. In this study, a technique was developed to detect the morphological change that occurs in the waveform of the intra-atrial electrogram during retrograde atrial activation. The method employed for waveform analysis is bas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 2004