Low intensity transcranial electric stimulation: Safety, ethical, legal regulatory and application guidelines.

نویسندگان

  • A Antal
  • I Alekseichuk
  • M Bikson
  • J Brockmöller
  • A R Brunoni
  • R Chen
  • L G Cohen
  • G Dowthwaite
  • J Ellrich
  • A Flöel
  • F Fregni
  • M S George
  • R Hamilton
  • J Haueisen
  • C S Herrmann
  • F C Hummel
  • J P Lefaucheur
  • D Liebetanz
  • C K Loo
  • C D McCaig
  • C Miniussi
  • P C Miranda
  • V Moliadze
  • M A Nitsche
  • R Nowak
  • F Padberg
  • A Pascual-Leone
  • W Poppendieck
  • A Priori
  • S Rossi
  • P M Rossini
  • J Rothwell
  • M A Rueger
  • G Ruffini
  • K Schellhorn
  • H R Siebner
  • Y Ugawa
  • A Wexler
  • U Ziemann
  • M Hallett
  • W Paulus
چکیده

Low intensity transcranial electrical stimulation (TES) in humans, encompassing transcranial direct current (tDCS), transcutaneous spinal Direct Current Stimulation (tsDCS), transcranial alternating current (tACS), and transcranial random noise (tRNS) stimulation or their combinations, appears to be safe. No serious adverse events (SAEs) have been reported so far in over 18,000 sessions administered to healthy subjects, neurological and psychiatric patients, as summarized here. Moderate adverse events (AEs), as defined by the necessity to intervene, are rare, and include skin burns with tDCS due to suboptimal electrode-skin contact. Very rarely mania or hypomania was induced in patients with depression (11 documented cases), yet a causal relationship is difficult to prove because of the low incidence rate and limited numbers of subjects in controlled trials. Mild AEs (MAEs) include headache and fatigue following stimulation as well as prickling and burning sensations occurring during tDCS at peak-to-baseline intensities of 1-2mA and during tACS at higher peak-to-peak intensities above 2mA. The prevalence of published AEs is different in studies specifically assessing AEs vs. those not assessing them, being higher in the former. AEs are frequently reported by individuals receiving placebo stimulation. The profile of AEs in terms of frequency, magnitude and type is comparable in healthy and clinical populations, and this is also the case for more vulnerable populations, such as children, elderly persons, or pregnant women. Combined interventions (e.g., co-application of drugs, electrophysiological measurements, neuroimaging) were not associated with further safety issues. Safety is established for low-intensity 'conventional' TES defined as <4mA, up to 60min duration per day. Animal studies and modeling evidence indicate that brain injury could occur at predicted current densities in the brain of 6.3-13A/m2 that are over an order of magnitude above those produced by tDCS in humans. Using AC stimulation fewer AEs were reported compared to DC. In specific paradigms with amplitudes of up to 10mA, frequencies in the kHz range appear to be safe. In this paper we provide structured interviews and recommend their use in future controlled studies, in particular when trying to extend the parameters applied. We also discuss recent regulatory issues, reporting practices and ethical issues. These recommendations achieved consensus in a meeting, which took place in Göttingen, Germany, on September 6-7, 2016 and were refined thereafter by email correspondence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk and safety of repetitive transcranial magnetic stimulation: report and suggested guidelines from the International Workshop on the Safety of Repetitive Transcranial Magnetic Stimulation, June 5-7, 1996.

Single-pulse transcranial magnetic stimulation (TMS) is a safe and useful tool for investigating various aspects of human neurophysiology, particularly corticospinal function, in health and disease. Repetitive TMS (rTMS), however, is a more powerful and potentially dangerous modality, capable of regionally blocking or facilitating cortical processes. Although there is evidence that rTMS is usef...

متن کامل

Non-Invasive Brain Stimulation for Enhancement of Corticospinal Excitability and Motor Performance

During the past .. years, non-invasive .rain stimulation has .ecome an emerging .eld in clinical neuroscience due to its capability to transiently modulate corticospinal excitability, motor and cognitive functions. .hereas transcranial magnetic stimulation has .een used e.tensively since more than t.o decades ago as a potential .neuromodulator., transcranial current stimulation .tCS. has more r...

متن کامل

Effects of transcranial direct current stimulation on pain intensity in patients with chronic low back pain: a systematic review of literature

Introduction: Low back pain (LBP) is common musculoskeletal disorder in today’s societies, which lead to inducing chronic pain and consequently pathological changes in brain function in most of the patients. Therefore, using effective intervention for controlling chronic pain in patients with LBP is very important. According to the evidence, some studies indicated that pain intensity is decreas...

متن کامل

Methodological Dimensions of Transcranial Brain Stimulation with the Electrical Current in Human

Transcranial current stimulation (TCS) is a neuromodulation method in which the patient is exposed to a mild electric current (direct or alternating) at 1-2 mA, resulting in an increase or a decrease in the brain excitability. This modi.cation in neural activities can be used as a method for functional human brain mapping with causal inferences. This method might also facilitate the treatments ...

متن کامل

Transcranial magnetic stimulation and the human brain: an ethical evaluation

Transcranial magnetic stimulation (TMS) is a neuroscientific technique that induces an electric current in the brain via application of a localized magnetic field pulse. The pulse penetrates the scalp and skull non-invasively and, depending on the parameters of stimulation, facilitates or depresses the local neuronal response with effects that can be transient or long lasting. While the mechani...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 128 9  شماره 

صفحات  -

تاریخ انتشار 2017