Electrochemical sensor with substitutional stripping voltammetry for highly sensitive endotoxin assay.

نویسندگان

  • Shinichiro Takano
  • Kumi Y Inoue
  • Satoko Takahashi
  • Kosuke Ino
  • Hitoshi Shiku
  • Tomokazu Matsue
چکیده

We have developed a novel method for detection of endotoxin with extra-high sensitivity by using substitutional stripping voltammetry (SSV). In this method, a p-aminophenol (pAP) conjugated peptide (Boc-Leu-Gly-Arg-pAP; LGR-pAP) was used as a substrate for a protease, which is activated at the last step of the endotoxin-induced Limulus amebocyte lysate (LAL) cascade reaction. Extra-highly sensitive detection of pAP liberated by the endotoxin-induced LAL reaction was successfully realized with SSV, based on the accumulation of an amperometric signal owing to exchange of the oxidation current of pAP generated at an electrode in a reaction cell with silver deposition on another electrode in a deposition cell. This reaction is driven by the difference in the redox potential between pAP/quinoneimine and silver/silver ion. The amount of the deposited silver is quantified by anodic stripping voltammetry (ASV). This SSV-based endotoxin assay was performed with a chip device comprising two cells, each of which was connected via a liquid junction made of Vycor® glass. The reaction cell and the deposition cell contained a standard endotoxin sample with LAL regents containing LGR-pAP and AgNO3 solution, respectively. After the cells were electrically connected for 60 min, ASV was conducted in the deposition cell to quantify the total electrical charge derived by the oxidation of free pAP in the reaction cell. The ASV signal increased with the increase of the endotoxin concentration in the sample solution in the range of 0.5-1000 EU L(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

متن کامل

Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide

A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Determination of epinephrine in the presence of uric acid and folic acid using nanostructure-based electrochemical sensor

Fabrication and electrochemical characterization of a sensor for the determination of epinephrine (EP), uric acid (UA) and folic acid (FA) is described. The sensor  was prepared using carbon paste electrode (CPE) modified with 3,4-dihydroxybenzaldehyde-2,4-dinitrophenylhydrazone (DDP) and carbon nanotubes (CNTs), which makes the modified electrode highly sensitive for the electrochemical detect...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 19  شماره 

صفحات  -