Comparison of Column Abundances from Three Infrared Spectrometers During AASE II
نویسندگان
چکیده
Three Fourier transform infrared (FTIR) spectrometers were on board the NASA DC-8 during the second Airborne Arctic Stratospheric Expedition (AASE II) in 1992. Two FTIRs used solar absorption and one used thermal emission. We compare over 2000 measurements from these 3 FTIRs, on 12 DC-8 flights, for closely coincident air masses and times, both inside and outside the polar vortex. In the majority of cases the offset biases are quite small, in the range 1-4%, and comparable to the absolute precisions expected. In most cases the rms scatter is in the range 4-11%; this scatter is unlikely to be geophysical, but rather is probably instrumental or analytical in origin.
منابع مشابه
Chemical Change in the Arctic Vortex During AASE II
We measured column abundances of HF, HCl, O3, HNO3, and H2O on the NASA DC-8 during the AASE II campaign, using thermal emission spectroscopy. We made multiple traversals of the Arctic vortex and surroundings. Using HF as a tracer, we remove the effects of subsidence from the measured column abundances; perturbations in the resulting column abundances are attributed to chemical processing. We f...
متن کاملCarbon dioxide column abundances at the Wisconsin Tall Tower site
[1] We have developed an automated observatory for measuring atmospheric column abundances of CO2 and O2 using near-infrared spectra of the Sun obtained with a high spectral resolution Fourier Transform Spectrometer (FTS). This is the first dedicated laboratory in a new network of ground-based observatories named the Total Carbon Column Observing Network. This network will be used for carbon cy...
متن کاملRetrieval algorithm for CO2 and CH4 column abundances from short-wavelength infrared spectral observations by the Greenhouse gases observing satellite
The Greenhouse gases Observing SATellite (GOSAT) was launched on 23 January 2009 to monitor the global distributions of carbon dioxide and methane from space. It has operated continuously since then. Here, we describe a retrieval algorithm for column abundances of these gases from the short-wavelength infrared spectra obtained by the Thermal And Near infrared Sensor for carbon Observation-Fouri...
متن کاملThe total carbon column observing network.
A global network of ground-based Fourier transform spectrometers has been founded to remotely measure column abundances of CO(2), CO, CH(4), N(2)O and other molecules that absorb in the near-infrared. These measurements are directly comparable with the near-infrared total column measurements from space-based instruments. With stringent requirements on the instrumentation, acquisition procedures...
متن کاملIMPROVED ATOMIC DATA FOR HO ii AND NEW HOLMIUM ABUNDANCES FOR THE SUN AND THREE METAL-POOR STARS
Improved energy levels and hyperfine structure constants for a selected set of Ho ii levels were measured from spectra recorded Q1 using the 1 m Fourier transform spectrometer (FTS) at the US National Solar Observatory. Branching fractions for the strong blue-UV lines from these levels were also measured from the FTS data and combined with earlier radiative lifetimes from time-resolved laser-in...
متن کامل