Aortic Relative Pressure Components Derived from Four-Dimensional Flow Cardiovascular Magnetic Resonance
نویسندگان
چکیده
PURPOSE To describe the assessment of the spatiotemporal distribution of relative aortic pressure quantifying the magnitude of its three major components. METHODS Nine healthy volunteers and three patients with aortic disease (bicuspid aortic valve, dissection, and Marfan syndrome) underwent 4D-flow CMR. Spatiotemporal pressure maps were computed from the CMR flow fields solving the pressure Poisson equation. The individual components of pressure were separated into time-varying inertial ("transient"), spatially varying inertial ("convective"), and viscous components. RESULTS Relative aortic pressure is primarily caused by transient effects followed by the convective and small viscous contributions (64.5, 13.6, and 0.3 mmHg/m, respectively, in healthy subjects), although regional analysis revealed prevalent convective effects in specific contexts, e.g., Sinus of Valsalva and aortic arch at instants of peak velocity. Patients showed differences in peak transient values and duration, and localized abrupt convective changes explained by abnormalities in aortic geometry, including the presence of an aneurysm, a pseudo-coarctation, the inlet of a dissection, or by complex flow patterns. CONCLUSION The evaluation of the three components of relative pressure enables the quantification of mechanistic information for understanding and stratifying aortic disease, with potential future implications for guiding therapy.
منابع مشابه
Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملTowards a comprehensive description of relative aortic pressure: insights from 4D flow CMR
Background A complete description of the relative spatiotemporal pressure gradients which drive blood flow has been a central goal of hemodynamics research over six decades. We have previously described a novel computational method for the in vivo estimation of these relative pressure gradients in the human cardiovascular system based on 4D flow Cardiovascular Magnetic Resonance (CMR) datasets ...
متن کاملFour-dimensional aortic blood flow patterns in thoracic aortic grafts.
Time-resolved cardiac gated three-directional velocity data obtained with magnetic resonance velocity-encoded phase contrast sequences were used to study blood flow patterns in thoracic aortic grafts. Twelve patients were studied, 6 with traumatic descending aortic pseudoaneurysms, 3 with atherosclerotic aneurysms, and 3 with dissecting aneurysms. All grafts had an inflow jet; outflow jet; and/...
متن کاملBeyond Bernoulli
BACKGROUND Transvalvular peak pressure drops are routinely assessed noninvasively by echocardiography using the Bernoulli principle. However, the Bernoulli principle relies on several approximations that may not be appropriate, including that the majority of the pressure drop is because of the spatial acceleration of the blood flow, and the ejection jet is a single streamline (single peak veloc...
متن کاملHemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications
Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Vari...
متن کامل