Radiation dose measurement in gastrointestinal studies.

نویسندگان

  • A Sulieman
  • M Elzaki
  • C Kappas
  • K Theodorou
چکیده

Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6 ± 10, 44.5 ± 49 and 35.7 ± 50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of the Adsorbed Radiation Dose to Eyelens During CT Scan and Radiotherapy of Nasopharynx Cancer

  Introduction: The study of the cause of death during the last few decades has shown that death due to infectious diseases has been declining and has been rising due to noninvasive diseases, especially cancers and accidents. Cancer is considered as one of the fatal diseases, and every year, more than 10.9 million people worldwide are diagnosed with the disease. Mater...

متن کامل

Gamma background radiation measurement in Lorestan province, Iran

Background: The exposure of human being to ionize radiation from natural sources is a continuing, inescapable feature of life on earth. Direct measurement of absorbed dose rates in air has been carried out in many countries of the world during the last few decades. Such investigations can be useful for assessment of public dose rates, the performance of epidemiological studies, and kee...

متن کامل

Absorbed dose to peripheral organs during different methods of dental radiology using radiation estimation models

Introduction: Dental radiography as one of the most frequent type of radiological examinations is accepted for medical investigations due to their significant benefits nevertheless using ionizing radiation. It has lower radiation dose compared to another radiological examination but because of its high application for children, radiation dose needs attention. Based on affectin...

متن کامل

Calculation of airkerma conversion factor to personal dose equivalent at various depths using the Monte Carlo Code GATE

Several studies have been done with the aim of improving the quality of the radiation protection measurement in radiology and nuclear medicine. Among  different subjects which are capable to be considered in this area, the measurement of the operational quantities of protection against the radiation ,such as, personal dose equivalent ,HP(d), at different depths (d=0.07mm, 3mm, 10mm) is an impor...

متن کامل

Protective effect of L-carnitine and vitamin E on gastrointestinal tract organs on male rats post radiation exposure

Background: Although ionizing radiation is a risk factor, it is a therapeutic agent for cancer. Objectives: The protective and defensive effect of L-Carnitine and vitamin E on gastrointestinal tract organs (liver, spleen and intestine) post whole body gamma irradiation exposure. Material and methods: 56 male albino rats, which were divided into four groups (14 rats per group); group (I): Contro...

متن کامل

Measurement of the Radiation Dose Rates of Patients Receiving Treatment with I-131 Using Telescopic Radiation Survey Meter

Introduction In order to discharge the patients receiving treatment with large radiation doses of 131I for thyroid cancer, it is necessary to measure and evaluate the external dose rates of these patients. The aim of the study was to assess a new method of external dose rate measurement, and to analyze the obtained results as a function of time. Materials and Methods In this study, a telescopic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 147 1-2  شماره 

صفحات  -

تاریخ انتشار 2011