AR2, a novel automatic muscle artifact reduction software method for ictal EEG interpretation: Validation and comparison of performance with commercially available software

نویسندگان

  • Shennan Aibel Weiss
  • Ali A Asadi-Pooya
  • Sitaram Vangala
  • Stephanie Moy
  • Dale H Wyeth
  • Iren Orosz
  • Michael Gibbs
  • Lara Schrader
  • Jason Lerner
  • Christopher K Cheng
  • Edward Chang
  • Rajsekar Rajaraman
  • Inna Keselman
  • Perdro Churchman
  • Christine Bower-Baca
  • Adam L Numis
  • Michael G Ho
  • Lekha Rao
  • Annapoorna Bhat
  • Joanna Suski
  • Marjan Asadollahi
  • Timothy Ambrose
  • Andres Fernandez
  • Maromi Nei
  • Christopher Skidmore
  • Scott Mintzer
  • Dawn S Eliashiv
  • Gary W Mathern
  • Marc R Nuwer
  • Michael Sperling
  • Jerome Engel
  • John M Stern
چکیده

Objective: To develop a novel software method (AR2) for reducing muscle contamination of ictal scalp electroencephalogram (EEG), and validate this method on the basis of its performance in comparison to a commercially available software method (AR1) to accurately depict seizure-onset location. Methods: A blinded investigation used 23 EEG recordings of seizures from 8 patients. Each recording was uninterpretable with digital filtering because of muscle artifact and processed using AR1 and AR2 and reviewed by 26 EEG specialists. EEG readers assessed seizure-onset time, lateralization, and region, and specified confidence for each determination. The two methods were validated on the basis of the number of readers able to render assignments, confidence, the intra-class correlation (ICC), and agreement with other clinical findings. Results: Among the 23 seizures, two-thirds of the readers were able to delineate seizure-onset time in 10 of 23 using AR1, and 15 of 23 using AR2 (p<0.01). Fewer readers could lateralize seizure-onset (p<0.05). The confidence measures of the assignments were low (probable-unlikely), but increased using AR2 (p<0.05). The ICC for identifying the time of seizure-onset was 0.15 (95% confidence interval (CI), 0.11-0.18) using AR1 and 0.26 (95% CI 0.21-0.30) using AR2.  The EEG interpretations were often consistent with behavioral, neurophysiological, and neuro-radiological findings, with left sided assignments correct in 95.9% (CI 85.7-98.9%, n=4) of cases using AR2, and 91.9% (77.0-97.5%) (n=4) of cases using AR1. Conclusions: EEG artifact reduction methods for localizing seizure-onset does not result in high rates of interpretability, reader confidence, and inter-reader agreement. However, the assignments by groups of readers are often congruent with other clinical data. Utilization of the AR2 software method may improve the validity of ictal EEG artifact reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epileptic seizure detection based on The Limited Penetrable visibility graph algorithm and graph properties

Introduction: Epileptic seizure detection is a key step for both researchers and epilepsy specialists for epilepsy assessment due to the non-stationariness and chaos in the electroencephalogram (EEG) signals. Current research is directed toward the development of an efficient method for epilepsy or seizure detection based the limited penetrable visibility graph (LPVG) algorith...

متن کامل

Prediction of Epileptic Seizures in Patients with Temporal Lobe Epilepsy (TLE) based on Cepstrum analysis and AR model of EEG signal

Epilepsy is a chronic disorder of brain function caused by abnormal and excessive electrical neurons discharge in the brain. Seizures cause disturbances in consciousness that occur without prior notice, so their prediction ability, based on EEG data, can reduce stress and improve quality of life. An epileptic patient EEG data consists of five parts: Ictal, Inter-Ictal, pre-Ictal, Post-Ictal, an...

متن کامل

Muscle artifact removal in ictal scalp-EEG based on blind source separation

Electroencephalogram (EEG) recordings are often contaminated with muscle artifacts. These artifacts obscure the EEG and complicate its interpretation or even make the interpretation unfeasible. This paper focuses on the particular context of extraction of low-voltage rapid ictal discharges from ictal scalp-EEG activity cantaminated by muscle artifact. In this context our aim was to evaluate the...

متن کامل

Real-time EEG artifact correction during fMRI using ICA

BACKGROUND Simultaneous acquisition of EEG and fMRI data results in EEG signal contamination by imaging (MR) and ballistocardiogram (BCG) artifacts. Artifact correction of EEG data for real-time applications, such as neurofeedback studies, is the subject of ongoing research. To date, average artifact subtraction (AAS) is the most widespread real-time method used to partially remove BCG and imag...

متن کامل

EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach

Introduction: Clinicians use several computer-aided diagnostic systems for depression to authorize their diagnosis. An electroencephalogram  (EEG) may be used as an objective tool for early diagnosis of depression and controlling it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. Methods: This work proposes a no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017