First experience with combined use of adaptive statistical iterative reconstruction and gemstone spectral imaging in spinal fusion CT images

نویسندگان

  • Fengdan Wang
  • Yan Zhang
  • Zhengyu Jin
  • Richard Zwar
چکیده

Objective. To explore whether the image noises and the metal artifacts could be further managed by the combined use of two technologies, the adaptive statistical iterative reconstruction (ASIR) and the monochromatic imaging generated by gemstone spectral imaging (GSI) dual-energy CT. Materials and Methods. Fifty-one patients with 318 spinal pedicle screws were prospectively scanned with dual energy CT by using fast kV-switching GSI between 80 and 140 kVp. The monochromatic GSI images at 110 keV were reconstructed either without ASIR or with ASIR of various levels (30%, 50%, 70% and 100%). For these five sets of images, both objective and subjective image quality assessments were performed to evaluate the image quality. Results. With objective image quality assessment, the metal artifacts (measured by an artifacts index) significantly decreased when increasing levels of ASIR was utilized (p < 0.001). Moreover, adding ASIR to GSI also decreased the image noise (p < 0.001) and improved the signalto-noise ratio (SNR, p < 0.001). With subjective image quality analysis, the inter-reader agreements were good, with intra-class correlation coefficients (ICC) of 0.89 to 0.99. Meanwhile, the visualization of the peri-implant soft tissue was improved at higher ASIR levels (p < 0.001). Conclusion. Combined use of ASIR and GSI is shown to decrease the image noise and improve the image quality in post-spinal fusion CT scans. Optimal results were achieved with ASIR levels of over 70%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility Study of Using Gemstone Spectral Imaging (GSI) and Adaptive Statistical Iterative Reconstruction (ASIR) for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values

PURPOSE To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. MATERIALS AND METHODS 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (grou...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Comparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques

Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...

متن کامل

Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study.

OBJECTIVE The purpose of this study was to evaluate the image noise, low-contrast resolution, image quality, and spatial resolution of adaptive statistical iterative reconstruction in low-dose body CT. MATERIALS AND METHODS Adaptive statistical iterative reconstruction was used to scan the American College of Radiology phantom at the American College of Radiology reference value and at one-ha...

متن کامل

SPECT-CT fusion in the diagnosis of hyperparathyroidism

Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015