Dynamic Response of a Group of Synchronous Generators following Disturbances in Distribution Grid

نویسندگان

  • Samir Avdaković
  • Alija Jusić
چکیده

Article history: Received: 22.10.2014. Received in revised form: 13.12.2015. Accepted: 14.12.2015. The connection of distributed sources and their impact on distribution grid has been the subject of intensive research in the last two decades. Creating a favorable environment for the production of electrical energy from renewable energy sources in many countries around the world made an evident increase in electrical energy production from renewable sources. Connecting these generators to distribution grid is not always an easy task, and often, in cases of inadequate analysis and poor choice of ways of connecting these sources, can have a negative impact on the quality of electrical energy in local distribution grids. In this paper, using a realistic test system, the focus of research is to identify the behavior of group synchronous generators connected to the medium-voltage distribution grid in "cascade" manner. The selected test system presents the real power distribution system of the Municipality of Gornji Vakuf-Uskoplje, to which six synchronous generators are connected at the moment. Analyses results of the work of this power distribution system in the previous period indicate that there have been significant changes in the existing distribution grid (significant change in voltage, increased losses, etc.) after these generators were connected. Dynamic simulations are conducted on the basis of the appropriate mathematical models, and the response of the generators and changes in the voltage value in the distribution grid were simulated for several types of disturbances. The results show that generators remain in synchronism while tested on selected simulated disturbances, where the oscillations of the generator rotor disappear over a period of several seconds. Also, the changes of voltage value in distribution grids for simulated disturbances are within the permitted limits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online Aggregation of Coherent Generators Based on Electrical Parameters of Synchronous Generators

This paper proposes a novel approach for coherent generators online clustering in a large power system following a wide area disturbance. An interconnected power system may become unstable due to severe contingency when it is operated close to the stability boundaries. Hence, the bulk power system controlled islanding is the last resort to prevent catastrophic cascading outages and wide area bl...

متن کامل

معرفی یک روش جدید برای تخمین به هنگام ناپایداری ولتاژ در شبکه های قدرت بر مبنای حفاظت گسترده شبکه

In this paper, the behavior of dynamic loads of a power system against voltage disturbances is investigated. Then a real electric grid, Khorasan electric grid in North-East of Iran, is modeled by dynamic model of generators, AVRs, governors, field current limiting systems and electric loads. The paper is continued by introducing a novel method, called VCI, for real time voltage instability dete...

متن کامل

Fast Transient Hybrid Neuro Fuzzy Controller for STATCOM During Unbalanced Voltage Sags

A static synchronous compensator (STATCOM) is generally used to regulate voltage and improve transient stability in transmission and distribution networks. This is achieved by controlling reactive power exchange between STATCOM and the grid. Unbalanced sags are the most common type of voltage sags in distribution networks. A static synchronous compensator (STATCOM) is generally used to maintain...

متن کامل

Dynamic Grid Support in Low Voltage Grids – Fault Ride-Through and Reactive Power/Voltage Support during Grid Disturbances

Faults in medium and high voltage grids lead to voltage sags in the low voltage level. Due to the voltage dip, distributed generators disconnect from the low voltage grid. Depending on the amount of disconnected generation, system stability could be compromised. With a dynamic grid support, distributed generators remain connected to the grid during faults, also called fault ride-through. Moreov...

متن کامل

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016