Chronic incomplete atrioventricular block induced by radiofrequency catheter ablation.
نویسندگان
چکیده
To determine if catheter ablation of the atrioventricular (AV) junction with radiofrequency energy can induce chronic incomplete (first- and second-degree) AV block to avoid the need for a permanent pacemaker, 20 closed-chest dogs were studied. Group 1 (10 dogs) received radiofrequency energy (750 kHz) with a fixed power setting (5 or 10 W) while increasing the pulse duration from 10 to 50 seconds for each application. Group 2 (10 dogs) received energy with a fixed pulse duration (20 or 30 seconds) while increasing the power setting from 5 to 10 W or from 10 to 20 W during each energy delivery. Radiofrequency energy was delivered between a chest-patch electrode and the distal electrode of a regular 7F tripolar His bundle catheter. For each application, the energy delivery was interrupted when 1) the PR interval prolonged (greater than 50%) or 2) second-degree or complete AV block occurred and persisted up to 5 seconds. The ablation procedure ended when there was 1) persistent PR prolongation (greater than 50%) or persistent second-degree AV block (lasting greater than 30 minutes) after ablation, 2) occurrence of two consecutive transient (less than 1 minute) complete AV blocks after each energy delivery, or 3) complete AV block (lasting greater than 2 minutes) after ablation. Of seven dogs in group 1 and five dogs in group 2 in which incomplete AV block was achieved 1 hour after the procedure, six in group 1 and five in group 2 remained in incomplete AV block 2-3 months after ablation. One dog in group 1 progressed into complete AV block. Of the remaining three dogs in group 1 and five dogs in group 2 in which complete AV block was initially achieved 1 hour after ablation, two in group 1 and four in group 2 continued to have complete AV block, whereas one in each group had AV conduction returned to incomplete at 1-2 months of follow-up. Thus, a total of 13 dogs had chronic incomplete AV block induced by radiofrequency catheter ablation. Pathologic examination of the conduction system in two dogs with first-degree AV block, two dogs with second-degree AV block, and one dog with complete AV block showed discrete scars involving the approaches to the AV node and the AV node itself. It is concluded that, in most dogs studied, chronic incomplete AV block could be achieved by careful titration of the dosage of radiofrequency energy and by regulation of the ablation end points.
منابع مشابه
Ablation of the atrioventricular junction with radiofrequency energy using a new electrode catheter.
Percutaneous catheter ablation using radiofrequency energy can be used to interrupt atrioventricular (AV) conduction in patients with supraventricular tachycardia refractory to drugs. Results of radiofrequency ablation of the AV junction using a custom-designed catheter with a large, 3-mm-long distal electrode, 2-mm interelectrode spacing, and a shaft with increased torsional rigidity were comp...
متن کاملComparison of late results of surgical or radiofrequency catheter modification of the atrioventricular node for atrioventricular nodal reentrant tachycardia.
AIMS Although arrhythmia surgery and radiofrequency catheter ablation to cure atrioventricular nodal reentrant tachycardia differ in technical concept, the late results of both methods, in terms of elimination of the arrhythmogenic substrate and procedure-related new and different arrhythmias, have never been compared. This constituted the purpose of this prospective follow-up study. METHODS ...
متن کاملCatheter cryoablation of cardiac arrhythmias.
PURPOSE OF REVIEW The purpose of the review is to provide an update on the safety and efficacy of catheter cryoablation. RECENT FINDINGS Catheter cryoablation is a safe and clinically effective method for ablation of atrioventricular nodal reentrant supraventricular tachycardia. Although the acute procedural success rate of catheter cryoablation for this arrhythmia may be slightly lower than ...
متن کاملElectroanatomic mapping and radiofrequency ablation of porcine left atria and atrioventricular nodes using magnetic resonance catheter tracking.
BACKGROUND The MRI-compatible electrophysiology system previously used for MR-guided left ventricular electroanatomic mapping was enhanced with improved MR tracking, an MR-compatible radiofrequency ablation system and higher-resolution imaging sequences to enable mapping, ablation, and ablation monitoring in smaller cardiac structures. MR-tracked navigation was performed to the left atrium (LA)...
متن کاملCatheter-induced mechanical trauma to fast and slow pathways during radiofrequency ablation of atrioventricular nodal reentry tachycardia: incidence, predictors, and clinical implications.
BACKGROUND Data on the incidence and significance of catheter-induced trauma to fast and slow pathways are scarce. OBJECTIVES To evaluate the incidence, predictors, and clinical implications of inadvertent catheter-induced mechanical trauma to fast and slow pathways during radiofrequency ablation (RFA) of atrioventricular nodal reentry tachycardia (AVNRT). METHODS A total of 901 consecutive...
متن کاملذخیره در منابع من