PURPOSE To assess the frequencies and sites of surgical glove perforations in lower extremity fracture surgery and hip joint replacement (HJR) surgery. Additionally, we also studied the usefulness of an indicator system glove. MATERIALS AND METHODS We assessed surgical glove perforations in 30 cases of lower extremity fracture surgery and 18 cases of HJR surgery conducted by one right handed 1st operator from April 2013 to July 2013. We assessed frequencies and sites of perforation in 152 gloves; 95 used in lower extremity fracture surgery and 57 used in HJR surgery. We studied the perforation rates and sites according to participants and operation types. Using the Biogel indicator system glove, which is well known as a fast indicator of glove perforation, we were also able to assess the time difference between operative participant detection of perforation and inspector nurse detection while observing in the operative field. RESULTS There were 18 of 30 cases in lower extremity fracture surgeries and 12 of 18 cases in HJR surgeries which had more than one surgical glove perforation event. Of all 152 gloves used, perforation occurred in 15 of 57 gloves (26.3%) in HJR surgery and 23 of 95 gloves (24.2%) in lower extremity fracture surgery. Perforation occurred more frequently in operators than assistant doctors or scrub nurses. The most frequent perforation site was the second digit of the left hand. On average, the time difference between operative participant notice of perforation and inspector nurse notice of perforation was 20.6 seconds. CONCLUSION The perforation of surgical gloves happened in approximately one out of every four persons. Importantly, we noted a 37.0% prevalence of glove perforation in 1st operators. Considering that glove perforation is a critical factor responsible for intra-operative infection, surgeons must be conscious of the risk of surgical glove perforation and use double gloving regularly. Furthermore, indicator double gloving is recommended for fast detection of outer glove perforation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Knee and Hip Joint Replacement Surgery in a Patient with Ochronotic Arthropathy: Surgical Tips

Ochronosis or black joints disorder is a rare autosomal recessive disorder caused by deficiency of homogentisic acidoxidase. Orthopaedic manifestations are common and mostly involve spine and large joints such as knee and hip.Arthropathy is progressive and will eventually leads to arthroplasty. Not being familiar with this disorder might lead todevastating complications. We present a 57 year-ol...

متن کامل

Study of Glove Perforation during Hip Replacement Arthroplasty: Its Frequency, Location, and Timing

Objective. The aim of the study was to evaluate the location, timing, and frequency of glove perforation during hip replacement arthroplasty. Methods. Gloves worn by surgical team members in 19 primary hip replacement arthroplasties were assessed. The study was of a single gloving system. All the used gloves were collected at the end of the surgery and assessed visually and by using water infla...

متن کامل

Increased awareness of glove perforation in major joint replacement. A prospective, randomised study of Regent Biogel Reveal gloves.

An intact barrier between the hands of the surgeon and the patient remains the single most important factor in protection against infection for both. Increasing the awareness of possible glove perforation without skin penetration will decrease the risk of contamination. We performed a prospective, randomised trial comparing the incidence of glove perforation using a new type of glove (Regent Bi...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Glove perforation and contamination in primary total hip arthroplasty.

We conducted a randomised, controlled trial to determine whether changing gloves at specified intervals can reduce the incidence of glove perforation and contamination in total hip arthroplasty. A total of 50 patients were included in the study. In the study group (25 patients), gloves were changed at 20-minute intervals or prior to cementation. In the control group (25 patients), gloves were c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2015