Critical evaluation of HPV16 gene copy number quantification by SYBR green PCR

نویسندگان

  • Ian Roberts
  • Grace Ng
  • Nicola Foster
  • Margaret Stanley
  • Michael T Herdman
  • Mark R Pett
  • Andrew Teschendorff
  • Nicholas Coleman
چکیده

BACKGROUND Human papilloma virus (HPV) load and physical status are considered useful parameters for clinical evaluation of cervical squamous cell neoplasia. However, the errors implicit in HPV gene quantification by PCR are not well documented. We have undertaken the first rigorous evaluation of the errors that can be expected when using SYBR green qPCR for quantification of HPV type 16 gene copy numbers. We assessed a modified method, in which external calibration curves were generated from a single construct containing HPV16 E2, HPV16 E6 and the host gene hydroxymethylbilane synthase in a 1:1:1 ratio. RESULTS When testing dilutions of mixed HPV/host DNA in replicate runs, we observed errors in quantifying E2 and E6 amplicons of 5-40%, with greatest error at the lowest DNA template concentration (3 ng/microl). Errors in determining viral copy numbers per diploid genome were 13-53%. Nevertheless, in cervical keratinocyte cell lines we observed reasonable agreement between viral loads determined by qPCR and Southern blotting. The mean E2/E6 ratio in episome-only cells was 1.04, but with a range of 0.76-1.32. In three integrant-only lines the mean E2/E6 ratios were 0.20, 0.72 and 2.61 (values confirmed by gene-specific Southern blotting). When E2/E6 ratios in fourteen HPV16-positive cervical carcinomas were analysed, conclusions regarding viral physical state could only be made in three cases, where the E2/E6 ratio was < or = 0.06. CONCLUSION Run-to-run variation in SYBR green qPCR produces unavoidable inaccuracies that should be allowed for when quantifying HPV gene copy number. While E6 copy numbers can be considered to provide a useable indication of viral loads, the E2/E6 ratio is of limited value. Previous studies may have overestimated the frequency of mixed episomal/integrant HPV infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absolute quantification of murine interleukine-4, interleukine- 10 and interferon-γ gene transcripts using Real Time PCR

The study of cytokines gene expression is quite important in various conditions of health and disease for the evaluation of clinical responses to new vaccination approaches. An absolute quantification is based on a calibration curve and production of standard controls to achieve more reliable results than in relative system. In this study we attempted to construct standard controls to evaluate ...

متن کامل

Design a Real Time PCR with SYBR Green for quantification of HTLV-1 proviral load for blood donors

Abstract Background and Objectives In Iran, Khorasan province is an endemic area for HTLV-1 virus. Considering the inability of serological tests to determine HTLV-1 in window period, their failure to confirm the indetermination results of western blot, and given the probability for HTLV-1 transfusion transmission, a SYBR green-based Real Time PCR was set to measure the HTLV-1 proviral load.  ...

متن کامل

Development of a real-time PCR assay using SYBR Green I for provirus load quantification in a murine model of AIDS.

A real-time PCR assay using SYBR Green I for quantification of provirus load in a murine model of AIDS (i.e., LP-BM5 infection) was developed and validated. In this method, data are normalized against the 18S rRNA gene. The method has a dynamic range of 8 logs and a sensitivity of one copy.

متن کامل

Evaluation of a homemade SYBR green I reaction mixture for real-time PCR quantification of gene expression.

Real-time PCR is an accurate method that can be used for the quantification of specific DNA molecules. Here we provide a protocol for SYBR Green I in real-time PCR applications using plastic reaction tubes. We report that SYBR Green I is alkali labile and once degraded inhibits the PCR. In our optimized protocol, diluted aliquots of SYBR Green I remain stable for at least two weeks. We also eva...

متن کامل

Real-time PCR based on SYBR-Green I fluorescence: An alternative to the TaqMan assay for a relative quantification of gene rearrangements, gene amplifications and micro gene deletions

BACKGROUND Real-time PCR is increasingly being adopted for RNA quantification and genetic analysis. At present the most popular real-time PCR assay is based on the hybridisation of a dual-labelled probe to the PCR product, and the development of a signal by loss of fluorescence quenching as PCR degrades the probe. Though this so-called 'TaqMan' approach has proved easy to optimise in practice, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Biotechnology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008