Acute and Mid-Term Results after Pulmonary Veins Isolation Using a Novel Circular Irrigated Multielectrode Mapping and Ablation Catheter (nMARQTM)

نویسندگان

  • Ibrahim Marai
  • Mahmoud Suleiman
  • Jonathan Lessick
  • Miry Blich
  • Sobhi Abadi
  • Monther Boulos
چکیده

Background: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation in both paroxysmal and persistent AF. However, this procedure is still challenging and time consuming. Objective: The aim of this study was to present our approach for PVI using a novel circular irrigated multielectrode mapping and ablation catheter (nMARQ) and to present acute and mid-term results. Methods: The study included 31 consecutive patients with symptomatic AF (4 had persistent and 27 had paroxysmal AF) who underwent PVI using the nMARQ catheter. Circular ablation was guided by CT image integrated into fast anatomical map and by intra cardiac echo. Isolation of pulmonary veins was identified using the nMARQ catheter if it was possible to advance it into the veins, otherwise Lasso catheter was used. Patients were followed up to 20 months. Results: PVI was achieved in 119 (98%) out of 121 pulmonary veins identified, and final PVI was obtained in 30 (97%) out of 31 patients. Lasso catheter was needed for PVI confirmation in 16 (52%) patients. Touch up ablation using standard catheter guided by Lasso catheter was needed in 4 (13%) patients. Pericardial tamponade occurred in 1 patient who was treated with pericardiocentesis. No other major complications were detected. During follow-up (mean 15.9 ± 3.6 months, range 9 20 months), 4 (13%) patients had recurrence of atrial tachyarrhythmia. Conclusion: PVI using the novel nMARQ catheter is safe with good acute and mid-term efficacy. Long term follow up trials are needed. How to cite this paper: Marai, I., Suleiman, M., Lessick, J., Blich, M., Abadi, S. and Boulos, M. (2016) Acute and Mid-Term Results after Pulmonary Veins Isolation Using a Novel Circular Irrigated Multielectrode Mapping and Ablation Catheter (nMARQTM). World Journal of Cardiovascular Diseases, 6, 477-488. http://dx.doi.org/10.4236/wjcd.2016.612051 Received: April 5, 2016 Accepted: December 27, 2016 Published: December 30, 2016 Copyright © 2016 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY 4.0). http://creativecommons.org/licenses/by/4.0/

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initial experience and treatment of atrial fibrillation using a novel irrigated multielectrode catheter: Results from a prospective two-center study.

BACKGROUND PV electrical isolation has become the cornerstone of catheter ablation for the treatment of atrial fibrillation (AF). Several strategies have been proposed to achieve this goal. The aim of this study was to assess the efficacy and safety of AF ablation using a new circular irrigated multielectrode ablation catheter designed to achieve single-delivery pulmonary vein (PV) isolation. ...

متن کامل

Circular mapping recordings in a persistent left superior vena cava during atrial tachycardia: Was isolation achieved?

Case presentation A 56-year-old woman was referred for recurrence of symptomatic paroxysmal AF and AT after pulmonary vein isolation (PVI). Preprocedure imaging demonstrated the presence of a PLSVC. Reconnection of right superior and right inferior pulmonary veins (PV) was observed, and both veins were successfully reisolated. Postisolation, AF initiated spontaneously multiple times. During map...

متن کامل

Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? Results from a prospective randomized study.

BACKGROUND Pulmonary vein (PV) isolation is a promising new treatment for atrial fibrillation (AF). We hypothesized that isolation of large areas around both ipsilateral PVs with verification of conduction block is more effective than the isolation of each individual PV. METHODS AND RESULTS A total of 110 patients, 67 with paroxysmal AF and 43 with persistent AF, were randomly assigned to und...

متن کامل

Sounding the warning on the potential for oesophageal injury resulting from use of the nMARQ™ for ablation of atrial fibrillation.

Catheter ablation of atrial fibrillation (AF) is now a commonly performed procedure throughout the world. Despite the widespread adoption of this procedure, it is well recognized that important limitations exist. These limitations include (i) less that optimal efficacy, especially when long-term success is considered; (ii) long procedure times and the requirement for considerable skill to perfo...

متن کامل

Verification of pulmonary vein isolation during single transseptal cryoballoon ablation: a comparison between the classical circular mapping catheter and the inner lumen mapping catheter.

AIMS Cryoballoon ablation has proven very effective in achieving pulmonary vein isolation (PVI). The novel Achieve inner lumen mapping catheter designed to be used in conjunction with the cryoballoon, serves as both a guidewire and a mapping catheter. To our knowledge, this is the first study comparing the latter to verification of electrical isolation with the 'traditional' circular mapping ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016