Effects on mother and fetus of epidural and combined spinal-epidural techniques for labor analgesia.

نویسندگان

  • Giane Nakamura
  • Eliana Marisa Ganem
  • Ligia Maria Suppo de Souza Rugolo
  • Yara Marcondes Machado Castiglia
چکیده

OBJECTIVE Epidural (EA) and combined spinal-epidural (CSE) techniques have both been utilized for labor analgesia. This study compared the effects on the mother and newborn of these techniques in labor analgesia and anesthesia. METHODS Forty pregnant women received epidural analgesia with 15 mL of 0.125% ropivacaine (EA group) and 5 microg of sufentanil plus 2.5mg bupivacaine in the subarachnoid space (CSE group). Pain intensity, sensory blockade level, latency time, motor block intensity, labor analgesia duration, epidural analgesia duration, maternal hypotension, and pruritus were evaluated. The newborns were evaluated by Apgar and the neurological and adaptive capacity score (NACS) developed by Amiel-Tison. RESULTS There were no significant statistical differences between groups for pain scores, latency time, sensory blockade level, and Apgar score. Motor block, labor analgesia duration, and epidural analgesia duration were greater in the CSE group, whose seven mothers had mild pruritus. The NACS were greater in the EA group after half, two, and 24 hours. Ninety five percent of EA group newborns and 60% of CSE group newborns were found to be neurologically healthy at the 24 hour examination. CONCLUSION EA and CSE analgesia relieved maternal pain during obstetric analgesia, but CSE mothers had pruritus and a longer labor. Newborns of mothers who received epidural analgesia showed the best NACS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined Spinal-Epidural Analgesia for Laboring Parturient with Arnold-Chiari Type I Malformation: A Case Report and a Review of the Literature

Anesthetic management of laboring parturients with Arnold-Chiari type I malformation poses a difficult challenge for the anesthesiologist. The increase in intracranial pressure during uterine contractions, coughing, valsalva maneuvers, and expulsion of the fetus can be detrimental to the mother during the process of labor and delivery. No concrete evidence has implicated high cerebral spinal fl...

متن کامل

Comparison of Epidural versus Entonox for Labor Analgesia in Nulliparous Women

 Introduction: The aim of this study is to compare the efficacy of epidural versus entonox methods for labor analgesia in nulliparous women.  Methods: This randomized controlled trial was performed on 84 nulliparous women with - pregnancy admitted to Imam Reza Hospital in 10 May 2010- 10 May 2011.  They were randomly divided into two groups 42 women inhaled entonox in active phase at the ...

متن کامل

Progress in analgesia for labor: focus on neuraxial blocks

Neuraxial analgesia is widely accepted as the most effective and the least depressant method of providing pain relief in labor. Over the last several decades neuraxial labor analgesia techniques and medications have progressed to the point now where they provide high quality pain relief with minimal side effects to both the mother and the fetus while maximizing the maternal autonomy possible fo...

متن کامل

Advances in labour analgesia

women. The ideal labour analgesia technique should dramatically reduce the pain of labour, while allowing the parturient to actively participate in the birthing experience. In addition, it should have minimal effect on the fetus or the progress of labour. New labour analgesia techniques approach this goal. This lecture will review these new methods of pain relief for the parturient and will hig...

متن کامل

Comparison of epidural analgesia with combined spinal-epidural analgesia for labor: a retrospective study of 6497 cases.

BACKGROUND Combined spinal-epidural analgesia provides rapid-onset analgesia with minimal motor block, but it is a more invasive technique than epidural analgesia and the risk of complications may be increased. This study compared the safety and effect on delivery of combined spinal-epidural and epidural analgesia in labor. METHODS A retrospective observational study was performed. Data were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista da Associacao Medica Brasileira

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2009