Integrating Quality Control Tests in a Computed Tomography System
نویسندگان
چکیده
Quality control (QC) is of primary importance for computed tomography systems to obtain reliable data for Non Destructive Testing (NDT). A QC protocol is pursued for the AIMEN dual detector CT by a software add-on update on the reconstruction and visualization software. Image quality parameters are considered following standards and other published papers: uniformity, noise, SNR, contrast, pixel size and spatial resolution. Geometrical values have also to be considered for the adjustments of the CT system, for the scale calibration and geometrical alignment corrections. A simple initial image calibration is proposed for the offset correction for further reconstruction. The aim of this protocol is to simplify the quality tests to be performed periodically in an inspection environment by an end-user. This is achieved by minimizing the number of image tests along with their integration in a unique software tool for reconstruction and visualization. It is also transferable to other CT systems and for digital detectors focused only on digital radiography.
منابع مشابه
Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملComparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...
متن کاملOptimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملReliability of Persian Early Computed Tomography Score in Patients with Brain Infarction
Background: The one-third middle cerebral artery (1/3 MCA) method and Alberta Stroke Program Early Computed Tomography Score (ASPECTS) were used to detect significant early ischemic changes on brain computed tomography (CT) of patients with acute stroke. We designed the Persian Early CT Score (PECTS) and compared it with the above systems. Methods: The tomograms were chosen from the stroke data...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کامل