Nitroblue tetrazolium reduction. False positive and false negative results.

نویسندگان

  • P Ashburn
  • M R Cooper
  • C E McCall
  • L R DeChatelet
چکیده

Quantitative and histochemical nitroblue with polycythemia vera and neoplasia astetrazolium reduction (NBT) tests were persociated with fever, as well as in those with formed on leukocytes of 13 patients with known bacterial infection. It is suggested polycythemia vera, seven with chronic that patients with neoplasia or polycygranulocytic leukemia, eight with neothemia vera may show a false positve plastic disease associated with fever, 16 reaction in the histochemical NBT test. with bacterial infection, and 13 healthy Conversely, the test was significantly lower control individuals. No significant differthan control in patients with chronic granences were detected in the quantitative ulocytic leukemia. Such patients might test between any of the groups studied. show a false negative reaction in the test The histochemical NBT test was signifeven if infection were present. icantly higher than control in the patients

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lysozyme activity and nitroblue-tetrazolium reduction in leukaemic cells.

The cytochemical methods for lysozyme and nitroblue-tetrazolium reduction have been used to study the blast cells of acute myeloid leukaemia. Both proved useful in characterizing the cases with predominant monocytic differentiation. THE DEMONSTRATION OF LYSOZYME ACTIVITY HELPED TO DEFINE TWO MAIN GROUPS: (a) with predominantly lysozyme-negative cells (myeloblastic-promyelocytic), and (b) with c...

متن کامل

Comparison of five tests used in the diagnosis of neonatal bacteraemia.

The neutrophil count, immature:total neutrophil ratio, C reactive protein assay, nitroblue tetrazolium test and an acridine orange leucocyte cytospin test were evaluated for the diagnosis of neonatal bacteraemia. The acridine orange leucocyte cytospin test gave the highest specificity and positive predictive accuracy, but was less sensitive than the neutrophil count, C reactive protein assay or...

متن کامل

Macroscopic enzyme histochemistry in myocardial infarction: use of coenzyme, cyanide, and phenazine methosulphate.

Transversely sectioned human heart slices, obtained at necropsy from normal subjects and from cases of recent myocardial infarction, were stained with the nitroblue tetrazolium (NBT) dehydrogenase macroreaction for the gross identification of recent myocardial infarction. The addition of nicotinamide adenine dinucleotide (NAD) to the incubating medium greatly improved the sensitivity of the met...

متن کامل

In-vitro Immunomodulatory Activity of extracts of Bauhinia vareigata Linn bark on Human Neutrophils

Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0c...

متن کامل

False Negative Fecal Occult Blood Test: Prozone Effect

Dear editor, the fecal occult blood test is the presently widely used screening laboratory test for colorectal cancer. At present, the test is usually based on an immunological diagnostic principle (1, 2). A false positive fecal occult blood is common and widely mentioned in literature. Nevertheless, the false negative is little mentioned in the paper. Here, the authors discuss the issue of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 1973