What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?
نویسندگان
چکیده
OBJECTIVES To clarify whether a shorter interval between three successive home blood pressure (HBP) readings (10 s vs. 1 min) taken twice a day gives a better prediction of the average 24-h BP and better patient compliance. DESIGN We enrolled 56 patients from a hypertension clinic (mean age: 60 +/- 14 years; 54% female patients). The study consisted of three clinic visits, with two 4-week periods of self-monitoring of HBP between them, and a 24-h ambulatory BP monitoring at the second visit. Using a crossover design, with order randomized, the oscillometric HBP device (HEM-5001) could be programmed to take three consecutive readings at either 10-s or 1-min intervals, each of which was done for 4 weeks. Patients were asked to measure three HBP readings in the morning and evening. All the readings were stored in the memory of the monitors. RESULTS The analyses were performed using the second-third HBP readings. The average systolic BP/diastolic BP for the 10-s and 1-min intervals at home were 136.1 +/- 15.8/77.5 +/- 9.5 and 133.2 +/- 15.5/76.9 +/- 9.3 mmHg (P = 0.001/0.19 for the differences in systolic BP and diastolic BP), respectively. The 1-min BP readings were significantly closer to the average of awake ambulatory BP (131 +/- 14/79 +/- 10 mmHg) than the 10-s interval readings. There was no significant difference in patients' compliance in taking adequate numbers of readings at the different time intervals. CONCLUSION The 1-min interval between HBP readings gave a closer agreement with the daytime average BP than the 10-s interval.
منابع مشابه
Comparison of auscultatory and oscillometric blood pressures.
OBJECTIVE To study the differences in blood pressure readings between the auscultatory and oscillometric (Dinamap model 8100; Critikon, Tampa, Fla) methods. DESIGN Survey of 2 blood pressure instruments. SETTING Public schools. PARTICIPANTS Seven thousand two hundred eight schoolchildren aged 5 through 17 years. MAIN OUTCOME MEASURE Blood pressure levels. RESULTS For all children comb...
متن کاملComparison of the Average of Five Readings with Averages from Fewer Readings for Automated Oscillometric Blood Pressure Measurement in an Outpatient Clinic
BACKGROUND AND OBJECTIVES The optimal number of consecutive measurements for obtaining an average blood pressure (BP) reading in clinical practice is yet undefined by research. This study aimed to compare readings obtained from an average of 5 with averages of 2, 3, and 4, sequential measurements. SUBJECTS AND METHODS Using an automated oscillometric device (BpTRU), BP measurement was conduct...
متن کاملDiscordant prevalence of hypertension using two different automated blood pressure measurement devices: a population-based study in Dar es Salaam (Tanzania).
OBJECTIVE The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS Within a population-based survey in Dar es Salaam (Tanzania), we sele...
متن کاملRapid oscillometric blood pressure measurement compared to conventional oscillometric measurement.
BACKGROUND There have been few reports studying the necessary interval between blood pressure measurements, after the initial rest period. METHODS Blood pressure was measured in 50 patients using the conventional oscillometric technique (COT) and the rapid oscillometric technique (ROT). RESULTS The difference between COT and ROT was -1.1 / -0.1 mmHg, which was not significantly different (p...
متن کاملComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of hypertension
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2009