Molecular magnetic resonance imaging of atrial clots in a swine model.

نویسندگان

  • Elmar Spuentrup
  • Bernd Fausten
  • Sylvia Kinzel
  • Andrea J Wiethoff
  • Rene M Botnar
  • Philip B Graham
  • Stephan Haller
  • Marcus Katoh
  • Edward C Parsons
  • Warren J Manning
  • Thomas Busch
  • Rolf W Günther
  • Arno Buecker
چکیده

BACKGROUND The detection and differentiation of intracardiac masses is still challenging and may include neoplasms and thrombi. The aim of this study was the investigation of a targeted, fibrin-specific contrast agent (EP-2104R) for molecular targeted magnetic resonance imaging (MRI) of left atrial clots. METHODS AND RESULTS Chronic human thrombi were surgically implanted in the left atrial appendage of 5 swine. Molecular MRI was performed with a navigator-gated, free-breathing, cardiac-triggered 3D inversion-recovery, black-blood, gradient-echo sequence before and after systemic administration of 4 micromol/kg EP-2104R. MR images were analyzed by 2 investigators, and the contrast-to-noise ratio was calculated. Location of clots was confirmed by autopsy, and the gadolinium concentration in the clots was assessed. Before contrast agent administration, thrombi were not visible on black-blood MR images. After contrast administration, all atrial clots (n=5) were selectively visualized as white spots with a high contrast-to-noise ratio (clot/blood, 29.7+/-8.0). The gadolinium concentration in the clots averaged 74+/-45 micromol/L. CONCLUSIONS The fibrin-specific MR contrast agent EP-2104R allows for selective and high-contrast visualization of left atrial clots by means of molecular targeted MRI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

A New Theranostic System Based on Gd2O3 NPs coated Polycyclodextrin Functionalized Glucose for Molecular Magnetic Resonance Imaging (MMRI).

Introduction: Recent advances in nanoscience and biomedicine have attracted tremendous attention over the past decade to design and construct multifunctional nanoparticles that combine targeting, therapeutic, and diagnostic functions with a single platform to overcome the problems of conventional techniques for diagnosis and therapy with minimal toxicity.   Materials ...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Use of Magnetic Resonance Imaging in Food Quality Control: A Review

Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 112 3  شماره 

صفحات  -

تاریخ انتشار 2005