Dynamic retentive force of a mandibular unilateral removable partial denture framework with a back-action clasp.

نویسندگان

  • I Park
  • M Eto
  • N Wakabayashi
  • M Hideshima
  • T Ohyama
چکیده

PURPOSE The purpose of this study was to investigate the dynamic retentive force of a mandibular unilateral distal-extension partial denture framework with a back-action clasp that was designed in a buccally tilted cast on a dental surveyor. The retention mechanism of this framework was analyzed in comparison with other typical unilateral and bilateral frameworks for the mandibular Kennedy class II case. MATERIALS AND METHODS Experimental gold alloy frameworks of three designs were repositioned to the master cast, and lifted upward to the vertical direction to the occlusal plane. The load required to dislodge each framework was recorded. The retentive force of each framework was determined by the maximum load in a dislodgment cycle. The bending strength of a plain clasp pattern of the same length as the clasp arm used in each framework was also measured by cantilever beam test. RESULTS The mean retentive force of the unilateral framework with a back-action clasp of relatively low bending strength was significantly higher (P < 0.01) than that of the unilateral framework with two Akers clasps of relatively high bending strength, and 70 to 80% of the bilateral framework with two Akers clasps on the edentulous side and a double Akers clasp on the contralateral side. The unilateral framework with a back-action clasp showed the greatest early load resistance in the dislodgment cycle among the three designs. CONCLUSION The reasonable retention mechanism was demonstrated by the unilateral framework with a back-action clasp.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexibility of the Retentive Arm of Acetal Resin Clasp versus Cast Clasps- an in Vitro Study

Restoration of esthetics is an important factor to consider in the fabrication of a removable partial denture (RPD) . 1 Several types of polymers and metal alloys have been used in RPD construction. Frequently, RPD clasps made from the same alloy as the metal framework. The most common alloys used for clasps are cobalt-chromium (Co-Cr) alloy and gold and titanium alloys, although these may be u...

متن کامل

Retainer design for unilateral extension base partial removable dental prosthesis by three-dimensional finite element analysis.

PURPOSE The purpose of this study was to evaluate the effect of differences in the retainer design on load on abutment teeth and displacement of the denture base in mandibular unilateral extension base partial removable dental prosthesis to determine the optimum design for a mechanically appropriate retainer. METHODS Three models were used. Each incorporating a removable denture with differen...

متن کامل

An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.

STATEMENT OF PROBLEM The use of metal clasps on anterior teeth may cause esthetic problems. Recently, acetal resins have been used as an alternative tooth-colored denture clasp material to improve esthetics. However, there are few studies to support acetal resin use. PURPOSE The purpose of this in vitro study was to compare the retentive force and deformation of acetal resin and cobalt-chromi...

متن کامل

Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture.

BACKGROUND/AIM Retentive force of removable partial denture (RPD) directly depends on elastic force of stretched retentive clasp arms (RCAs). During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs. This study was based on analyzing properties of clasps designed by conventional clasp wax profi...

متن کامل

Mandibular Kennedy Class I partial denture management by broad stress distribution philosophy (radiographic assessment)

PURPOSE The objective of this study was radiographic assessment of the premolar teeth abutments alveolar bone resorption in mandibular Kennedy Class I removable partial denture (RPD) utilizing the broad stress distribution philosophy, either designed with multiple circlet clasp or compound Aker clasp. MATERIALS AND METHODS Twelve patients were enrolled for this study with upper completely ede...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical and dental sciences

دوره 48 4  شماره 

صفحات  -

تاریخ انتشار 2001