Efficiency of blood culture bottles for the fungal sterility testing of corneal organ culture media.

نویسندگان

  • G Thuret
  • A Carricajo
  • A C Vautrin
  • H Raberin
  • S Acquart
  • O Garraud
  • P Gain
  • G Aubert
چکیده

BACKGROUND/AIM The consequences of fungal contamination of an organ cultured cornea, though exceptional, are often disastrous for the recipient. Consequently, eye banks often quarantine corneas for 10 days or more before passing them for grafting. This period, though detrimental to the endothelial cell density of the delivered cornea, is necessary to detect contamination using conventional microbiological methods. The authors previously validated the use of a pair of aerobic and anaerobic blood bottles for sensitive and rapid detection of bacteria. To allow a short quarantine period, it remained only to optimise detection of fungi. The authors aimed to compare sensitivity and rapidity of fungal contamination detection by three methods: blood bottles, Sabouraud, and daily visual inspection of the organ culture medium. METHODS Four inocula (10(6), 10(4), 10(2), 10 colony forming unit (CFU) per ml) of 11 fungi (Candida albicans, C tropicalis, C glabrata, Saccharomyces cerevisiae, Rhodotorula rubra, Cryptococcus neoformans, Fusarium oxysporum, Aspergillus niger, A fumigatus, A flavus, Acremonium falciforme) were inoculated in a commercial organ culture medium containing a coloured pH indicator (CorneaMax, Eurobio, Les Ulis, France). The real live fungal inoculum was verified immediately after inoculation. After 48 hours at 31 degrees C, samples of the contaminated media were inoculated in three blood bottles: Bactec Aerobic/F, Bactec Mycosis IC/F, and Bactec Myco/F Lytic (Becton Dickinson, Le Pont de Claix, France), then placed in a Bactec 9240 rocking automat, and in four Sabouraud media (solid and liquid, 28 degrees C and 37 degrees C) with daily observation. Contaminated organ culture media were also checked daily for any change in turbidity and/or colour. Experiments were performed in triplicate. RESULTS Mycosis IC/F and Myco/F Lytic bottles were neither faster nor more sensitive than the aerobic bottle. The three methods were positive for all inocula, even the lowest (viable inoculum below 10 CFU/ml for each fungus). Contamination was detected within 24 hours by the aerobic bottles in 91% (40/44), by Sabouraud in 98% (43/44) (no significant difference) and by visual inspection in 66% of cases (29/44) (p<0.001 with the two others). Maximum times to detection were 46, 48 and 72 hours respectively. CONCLUSION This study further counters the preconception that fungal contamination is hard to detect in corneal organ culture media. This study is the last step in validating the use of a pair of blood bottles for the sterility testing of organ culture media, this time for fungi. Their use should make it possible to shorten microbiological quarantine and thus deliver corneas with higher endothelial cell density, without increasing the risk of recipient contamination.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungi.

AIMS To test the bactericidal activity of standard organ culture medium, and to compare the sensitivity and rapidity of blood culture bottles with conventional microbiological methods for detection of bacteria and fungi inoculated in a standard cornea organ culture medium. METHODS The bactericidal activity of contaminated standard organ culture medium containing 100 IU/ml penicillin, 0.1 mg/m...

متن کامل

A dedicated fungal culture medium is useful in the diagnosis of fungemia: a retrospective cross-sectional study

BACKGROUND Mortality for candidemia ranges from 15% to 35%. Current guidelines recommend inoculating blood into three aerobic and three anaerobic blood culture bottles when candidemia is suspected, without mention of a fungal blood culture bottle. OBJECTIVE To determine the value of the BACTEC Myco/F Lytic blood culture media in the diagnosis of fungemia. METHODS A two-year retrospective cr...

متن کامل

Method for sterility testing of corneal storage and transport media after removal of interfering antimicrobials: prospective validation study in compliance with the European Pharmacopoeia

Objective This study aimed at validating the method for sterility testing of the corneal culture medium, TISSUE-C, and the transport/deswelling medium, CARRY-C, according to the method suitability test, as defined by the European Pharmacopoeia (EP), using RESEP, which is a new medical device for removal of antimicrobial agents and an automated culture system. Methods and analysis The six EP r...

متن کامل

Lack of requirement for blind subcultures of BACTEC blood culture media.

To determine the need for blind subculturing of BACTEC (Johnston Laboratories, Cockeysville, Md.) blood culture media, we compared results of radiometric readings, visual inspection, and blind subculturing for nearly 7,500 blood specimens. Visual inspection and radiometric testing were performed on day 1 through 7, and blind subcultures were made on day 3. In the first phase of the study, 402 o...

متن کامل

بررسی عوامل اتیولوژیک و حساسیت آنتی بیوتیکی آنها در بیماران با زخم قرنیه

Introduction & Objective: Corneal ulcer is one of the most important medical emergencies that in the absence of on time diagnosis and treatment can lead to loss of vision. Therefore, identification of microorganisms and their response to drugs in each region is important. The aim of this study was to determine the most common organisms that cause keratitis and antibiotic sensitivity in this reg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 89 5  شماره 

صفحات  -