A 46-year-old man with a history of sustained monomorphic ventricular tachycardia underwent an implantation of a third generation multiprogrammable implantable cardioverter defibrillator. One year post implant, while manipulating a remote control to a radiofrequency modulated toy car, the patient experienced a defibrillator discharge not preceded by an arrhythmia prodrome. Subsequent interrogation of the defibrillator revealed that a 34-joule shock had been delivered and had been preceded by RR intervals ranging from 141-406 msec, consistent with sensing lead noise. The remote control utilizes a 12-volt battery and has a carrier frequency of 75.95 MHz and a modulating frequency of 50 Hz. Evaluation of the remote control and defibrillator interaction revealed that the remote control was able to trigger tachyarrhythmia sensing and reproduce the clinical episode. Interference was present only when the remote control was within 8 cm of the pulse generator and at specific angles relative to the device and only when the antenna length was > 45 cm. Interference was eliminated when a ground wire was attached to the antenna and when an aluminium shield was placed between the pulse generator and the remote control. This case report suggests that patients with third generation multiprogrammable defibrillators should be cautioned against close contact with potential sources of electromagnetic interference, such as remote control units.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Bipolar Radiofrequency Neurotomy to Treat Neck and Back Pain in Patients with Automatic Implantable Cardioverter Defibrillator.

We report 2 cases of successful treatment of neck and back pain with bipolar radiofrequency ablation (RFA) of the cervical and lumbar facet joints in patients with an automatic implantable cardioverter defibrillator (AICD).Two patients with complex cardiac histories and AICD devices were treated with bipolar RFA of the facet joints. One presented with axial neck pain and the other with axial ba...

متن کامل

تأثیر آموزش مبتنی بر الگوی خودمراقبتی اورم بر توان خودمراقبتی بیماران دارای دفیبریلاتور قلبی قابل کاشت (ICD)

  Background & Aim: Several studies have shown that the self-care activity of patients with implantable cardioverter defibrillator is inadequate. This study was conducted to assess the effect of an educational program based on the Orem’s self-care model in self-care ability of the patients .   Methods & Materials: This clinical trial was conducted among 66 patients with implantable cardiove...

متن کامل

[Radiofrequency catheter ablation of ventricular tachycardia in patients with an implantable defibrillator. Long-term follow-up].

INTRODUCTION AND OBJECTIVES The frequent occurrence of ventricular tachycardia can be a serious problem for patients with an implantable defibrillator, and may necessitate adjuvant antiarrhythmic therapy or radiofrequency catheter ablation. We analyzed the long-term results obtained with this latter therapy in patients suffering from frequent or continuous ventricular tachycardia. PATIENTS AN...

متن کامل

Electromagnetic Interference With Implantable Cardiac Devices

Although pacemakers and implantable cardioverter-defibrillators (ICDs) are subject to electromagnetic interference (EMI) from many sources, relatively few are capable of causing clinically significant interference. However, in the rapidly evolving technology -driven environment in which we live, new devices that could theoretically cause interference with implanted devices constantly appear bot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 16 8  شماره 

صفحات  -

تاریخ انتشار 1993