GPU-based ultrafast IMRT plan optimization.

نویسندگان

  • Chunhua Men
  • Xuejun Gu
  • Dongju Choi
  • Amitava Majumdar
  • Ziyi Zheng
  • Klaus Mueller
  • Steve B Jiang
چکیده

The widespread adoption of on-board volumetric imaging in cancer radiotherapy has stimulated research efforts to develop online adaptive radiotherapy techniques to handle the inter-fraction variation of the patient's geometry. Such efforts face major technical challenges to perform treatment planning in real time. To overcome this challenge, we are developing a supercomputing online re-planning environment (SCORE) at the University of California, San Diego (UCSD). As part of the SCORE project, this paper presents our work on the implementation of an intensity-modulated radiation therapy (IMRT) optimization algorithm on graphics processing units (GPUs). We adopt a penalty-based quadratic optimization model, which is solved by using a gradient projection method with Armijo's line search rule. Our optimization algorithm has been implemented in CUDA for parallel GPU computing as well as in C for serial CPU computing for comparison purpose. A prostate IMRT case with various beamlet and voxel sizes was used to evaluate our implementation. On an NVIDIA Tesla C1060 GPU card, we have achieved speedup factors of 20-40 without losing accuracy, compared to the results from an Intel Xeon 2.27 GHz CPU. For a specific nine-field prostate IMRT case with 5 x 5 mm(2) beamlet size and 2.5 x 2.5 x 2.5 mm(3) voxel size, our GPU implementation takes only 2.8 s to generate an optimal IMRT plan. Our work has therefore solved a major problem in developing online re-planning technologies for adaptive radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

WE-E-BRB-09: A GPU-Based Monte Carlo QA Tool for IMRT and VMAT.

PURPOSE To develop a GPU-based Monte Carlo (MC) 3D dosimetry quality assurance (QA) tool employing patient geometry and actual delivery information. METHODS First, we generate fluence maps at all beam angles from the initial treatment plan. A GPU-based MC dose engine, gDPM, is employed for the secondary dose calculation (SDC) on patient CT. This SDC is used to verify the TPS plan dose (PD) ac...

متن کامل

GPU-based ultra-fast dose calculation using a finite size pencil beam model.

Online adaptive radiation therapy (ART) is an attractive concept that promises the ability to deliver an optimal treatment in response to the inter-fraction variability in patient anatomy. However, it has yet to be realized due to technical limitations. Fast dose deposit coefficient calculation is a critical component of the online planning process that is required for plan optimization of inte...

متن کامل

A study of quality control method for IMRT planning based on prior knowledge and novel measures derived from both OVHs and DVHs.

Intensity-Modulated Radiation Therapy (IMRT) mathematically forms a large-scale optimization problem. The development of an IMRT plan is computationally expensive resulting in time-consuming, inefficient, and difficult to develop high-quality IMRT plans. By combining prior knowledge with proposed novel measures derived from both Overlap Volume Histogram (OVH) descriptors and Dose Volume Histogr...

متن کامل

Treatment Planning Considerations Using IMRT

Introduction ...........................................................103 IMRT or 3DCRT? ...................................................105 The MSKCC IMRT Planning Process....................107 Patient Selection • Patient Simulation And Structure Localization • Selection Of Beam Energy, Number, And Direction • Optimization • Conversion Of Intensity Profiles To Leaf Motion • Forward Dose ...

متن کامل

Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.

Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and characteristics of the MLC, the deliverable intensity distributions often differ f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 54 21  شماره 

صفحات  -

تاریخ انتشار 2009