Effect of iterative reconstruction on image quality in evaluating patients with coronary calcifications or stents during coronary computed tomography angiography: a pilot study
نویسندگان
چکیده
OBJECTIVE To determine the effect of "Iterative Reconstruction in Image Space" (IRIS) on image quality by comparing reconstructions of both medium and sharp kernels when evaluating coronary calcifications or stents during coronary computed tomography (CT) angiography. METHODS Thirty one consecutive patients were scanned with an electrocardiogram-gated helical technique on a dual-source CT system. Image reconstruction was performed using standard filtered back projection (FBP) and IRIS algorithm on both medium and sharp kernels (B26f, I26f, B46f, I46f). Each reconstruction was derived from the same raw data. Two blinded readers graded image quality using a five-point scale. Noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) were obtained. Noise was derived from the ascending aorta and left ventricle. SNR was obtained from sinus Valsalva, interventricular septum, and coronary vessels. CNR was obtained from septum, coronary vessels, and left ventricle. Comparisons of paired results between FBP and IRIS images were analyzed using the repeated measures analysis of variance method. Interreader correlation was assessed using weighted Kappa statistic. RESULTS Noise values of the ascending aorta and left ventricle were significantly lower in the images reconstructed with IRIS than those reconstructed with FBP for the evaluation of the same filters. SNR and CNR values were higher in the IRIS images (p<0.05). Interreader agreement for four reconstructions was interpreted as moderate (κ=0.40-0.59). CONCLUSION IRIS significantly reduced image noise and improved imaging of coronary calcifications or stents. When combined with a sharp kernel, IRIS can improve image quality by reducing the negative effects of decreased signal that may result from using a sharp kernel.
منابع مشابه
Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملThe effect of iterative reconstruction on image quality in evaluating patients with coronary calcifications or stents at coronary computed tomography angiography
Coronary computed tomography angiography (CCTA) is the most common non-invasive diagnostic tool currently used to exclude coronary artery disease. It is the only modality which enables direct visualization of coronary stents and concealed major complications such as stent fracture, in-stent restenosis, or thrombosis. CCTA is complicated in the presence of coronary calcification or stents as it ...
متن کاملEvaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction.
PURPOSE To prospectively compare traditional filtered back projection (FBP) and iterative image reconstruction for the evaluation of heavily calcified arteries with coronary computed tomography (CT) angiography. MATERIALS AND METHODS The study had institutional review board approval and was HIPAA compliant. Written informed consent was obtained from all patients. Fifty-five consecutive patien...
متن کاملIterative image reconstruction techniques: Applications for cardiac CT.
BACKGROUND Traditional limitations of cardiac CT are related to image noise, blooming artifacts from calcifications and stents, and radiation exposure. We evaluated whether these limitations can be ameliorated by the use of iterative reconstruction in image space (IRIS) instead of traditional filtered back projection (FBP) image reconstruction techniques. METHODS We compared image reconstruct...
متن کاملUsefulness of 16-slice multislice spiral computed tomography for follow-up study of coronary stent implantation.
BACKGROUND Although multislice spiral computed tomography (MSCT) is a promising technique for non-invasive coronary angiography, its usefulness in patients with stent implantation remains unclear. The aim of the present study was to compare the usefulness of MSCT with that of invasive coronary angiography for evaluating coronary stent patency. METHODS AND RESULTS Thirty-one patients were enro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -