Pharmacokinetic parameter sets of alfentanil revisited: optimal parameters for use in target controlled infusion and anaesthesia display systems.

نویسندگان

  • N Sigmond
  • M Baechtold
  • P M Schumacher
  • V Hartwich
  • T W Schnider
  • M Luginbühl
چکیده

BACKGROUND In open TCI and anaesthesia display systems, the choice of pharmacokinetic (PK) parameter sets of opioids is clinically relevant. Accuracy and bias of the PK models may be affected by administration mode and the co-administered hypnotic drug. We retrospectively evaluated the performance of eight PK parameter sets for alfentanil in two data sets (infusion and bolus application). METHODS With the dosing history from two studies in orthopaedic patients anaesthetized with propofol or inhalation anaesthetics the alfentanil plasma concentration over time was calculated with eight PK parameter sets. Median absolute performance error (MDAPE), log accuracy, median performance error (MDPE), log bias, Wobble, and Divergence were computed. Mann-Whitney rank test with Bonferroni correction was used for comparison between bolus and infusion data, repeated measures analysis of variance on ranks was used for comparison among parameter sets. RESULTS The parameters by Scott (original and weight adjusted) and Fragen had a MDAPE ≤30% and a median log accuracy <0.15 independent of the administration mode, while MDPE was within ±20% and log bias nearly within ±0.1, respectively. The sets by Maitre and Lemmens were within these limits only in the bolus data. All other parameter sets were outside these limits. CONCLUSIONS In healthy orthopaedic patients, the PK parameters by Scott and by Maitre were equally valid when alfentanil was given as repeated boluses. When given as infusion, the Maitre parameters were less accurate and subject to a significant bias. We cannot exclude that the difference between bolus and infusion is partially because of the different hypnotics used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of alfentanil target-controlled infusion in normal and morbidly obese female patients.

BACKGROUND Available alfentanil pharmacokinetic (PK) sets for target-controlled infusion (TCI) were derived from populations with normal BMI. The performance and accuracy of the models devised by Maitre and colleagues and Scott and colleagues were evaluated in a population including morbidly obese patients. METHODS Alfentanil TCI using Maitre and colleagues' model was administered to 10 obese...

متن کامل

Gender differences in the pharmacokinetics of propofol in elderly patients during and after continuous infusion.

Differences in the pharmacokinetics of propofol between male and female patients during and after continuous infusion have not been described in detail in patients aged 65 yr and older. To increase our insight into the pharmacokinetics of propofol in this patient population and to obtain pharmacokinetic parameters applicable in target controlled infusion (TCI), the pharmacokinetics of propofol ...

متن کامل

An evaluation of the accuracy of pharmacokinetic data for the computer assisted infusion of alfentanil.

The accuracy of using average alfentanil pharmacokinetic data in a computer assisted infusion pump (TIAC) to predict alfentanil plasma concentrations was tested in 35 patients (divided into three groups) receiving alfentanil and nitrous oxide in oxygen anaesthesia for lower and upper abdominal surgery. By frequently measuring the arterial plasma concentration, it was possible to determine the a...

متن کامل

Patient maintained alfentanil target-controlled infusion for analgesia during extracorporeal shock wave lithotripsy.

PURPOSE The purpose of this study was to determine whether alfentanil given by a pharmacokinetic-based target controlled infusion (TCI) system under patient control is a suitable analgesic technique for extracorporeal shock wave lithotripsy (ESWL). METHODS The design was an open, unblinded, noncomparative, prospective study. Forty outpatients undergoing ESWL were given patient maintained alfe...

متن کامل

Comparison of infusions of alfentanil or pethidine for sedation of ventilated patients on the ITU.

Sedation was studied in 30 patients requiring overnight ventilation in the intensive therapy unit (ITU). Patients received an infusion of either alfentanil or pethidine, supplemented with midazolam. The infusion rates were adjusted to provide optimal sedation as judged by a nurse, and measurements were made of quality of sedation, recovery and serum cortisol concentration. In addition, blood co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 111 2  شماره 

صفحات  -

تاریخ انتشار 2013