Influence of the PMMA and the ISO Slab Phantom for Calibrating Personal Dosemeters

نویسندگان

  • M. Ginjaume
  • X. Ortega
  • A. Barbosa
چکیده

INTRODUCTION Wide agreement has been reached among the main Bodies and Organizations involved in standardization of radiation protection to define as operational quantity for individual monitoring of external exposure, the personal dose equivalent, Hp(d) (1,2,3). However, as Hp(d) is defined in the human body, it is not a measurable quantity. In practice, it has to be estimated from the indication of an individual dosemeter, which is worn on the trunk and calibrated on a suitable phantom. The calibration phantom should provide a backscatter contribution, similar to that of the part of the body where the dosemeter is worn. Since its definition in 1985 (4), several reports have been published to clarify and define the experimental set up to be used for the calibration of dosemeters in terms of the above-mentioned quantity. Although the ICRU sphere was first considered to be a good phantom, its practical use presented so many difficulties that it was rejected. On the other hand, other phantoms such as the PMMA slab phantom of different sizes or the IAEA cubic water phantom were adopted. In 1992, ICRU, in its report 47 (5), gave a list of five different phantoms that were being used by several laboratories and were considered to be accurate enough within an accepted overall uncertainty in most radiation protection measurements of 30 %. ICRU 47 also included a new quantity to be used for calibration, which is defined as Hp(d) in a phantom which has the composition of ICRU tissue and the same size and shape as the calibration phantom. In the following text, this phantom will be named as the ICRU phantom. Nevertheless, to achieve uniformity in calibration procedures, ICRU 47 recommended the 30 cm x 30 cm x 15 cm PMMA slab phantom. However, recently, the International Organization for Standardization (ISO), in ISO 4037-3 (3), has proposed another phantom, which will be named, in this text, the ISO phantom, which consists of a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (front wall 2.5 mm thick). Many studies, such as the works from Grosswendt (6) and Gualdrini and Morelli (7), have analysed the characteristics of several practical calibration phantoms by means of Monte Carlo codes for photon transport. Calculations confirm that the new ISO phantom is a better substitute of the ICRU phantom than the PMMA phantom, mainly at low photon energies. The values for the personal dose equivalent for the ISO phantom are found to be very close to those calculated for the theoretical ICRU phantom, thus indicating that, in practice, backscatter correction factors are not needed in this new phantom. In 1995, the secondary calibration Laboratory from the Institute of Energy Technology (INTE) at the Technical University of Catalonia in Barcelona, Spain, agreed with the Spanish National Laboratory to adopt the ICRU recommended PMMA phantom, and to improve calibration procedure accuracy by introducing a correction factor for backscatter differences in PMMA and ICRU tissue (8). Such corrections were of the order of 8 % for the low-energy X-ray qualities. In 1999, before implementing the new ISO standard the INTE laboratory carried out the present work, whose aim was to estimate the influence of both phantoms when calibrating personal dosemeters with photons in the range 33 keV, 1.5 MeV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental study for improving the angle dependence of the response ofPADC-based personal neutron dosemeters

The large angle dependence of the Hp(10) response in PADC-based personal neutron dosemeters constitutes a serious concern in operational radiation protection dosimetry. For planar dosemeters, the typical Hp(10) response falls by half or more when the incidence angle changes from 0 to 60 . To reduce this source of systematic uncertainty, configurations based on multiple detectors at different an...

متن کامل

A new photon branch in the standard Panasonic UD-802 Dose Algorithm at the CIEMAT External Dosimetry Service

The standard dose algorithm provided by Panasonic to be used with the four element UD-802 TLD badge is widely employed in Personnel Dosimetry Services all around the world. The algorithm was developed to satisfy the obsolete standard ANSI 13.11-1983 that was reviewed in 1993 (HPS N13.11-1993) and revised again in 2001 (HPS N13.11-2001) including differences in the NIST x-ray techniques used as ...

متن کامل

Backscattering factor for some personal dosimeters and impact on Hp\(10\)

In the present paper, we estimated backscattering factors for the TLD and active personal dosimeters using 662 keV gamma-ray photons on a PMMA surface, which are, for the TLD, 1.12; Dosicard, 1.116; DRD, 0.99; and Saphydose, 1.073, and on a water slab phantom surface; for the TLD, 1.115; Dosicard, 1.112; DRD, 1; and Saphydose, 1.059. The backscattering factor contribution for the Saphydose is n...

متن کامل

A study on slab-wooden dust-slab phantom for the development of thorax phantom

Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom.  Materials and Methods: Th...

متن کامل

Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology.

The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y(-1) averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000