High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

نویسنده

  • Michael Woodman
چکیده

The Agilent 1290 Infinity LC System with ultraviolet/visible (UV/VIS) Diode Array detection (DAD) is used to analyze triglycerides in soybean oil under non-aqueous reversed phase gradient conditions. The Agilent 1290 Infinity LC System was used for the chromatographic separation of the sample on 3.0 and 2.1 mm id C18 columns, of various lengths, with 1.8-μm packing materials prepared in 600 bar (9000 psi) or special 1200 bar (18,000 psi) configurations. The ability of the Agilent 1290 Infinity LC System to operate with long, high resolution columns is demonstrated with isopropanol (IPA) or methyl tert butyl ether (MTBE) as the strong solvent and acetonitrile as the weak component of the mobile phase mixture. Authors

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

QbD Based Method Development on an Agilent 1290 Infinity UHPLC System Combined with a Seamless Method Transfer to HPLC Using Intelligent System Emulation Technology

In this Application Note, a method was developed on sub-2 μm particle columns and transferred to a conventional HPLC method using Quality by Design (QbD) principles. A seamless method transfer between the different chromatography systems was achieved using the Agilent Intelligent System Emulation Technology (ISET). Initial method development work on the Agilent Infinity 1290 system included aut...

متن کامل

Analysis of fat-soluble vitamins from food matrix for nutrition labeling

This Application Note shows how to carry out qualitative and quantitative analysis of fat soluble vitamins from two different food matrixes. A robust reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous determination of nine fat soluble vitamins was developed. Separation and quantification was achieved by an Agilent 1260 Infinity LC System using an Agilent Por...

متن کامل

High-Resolution Sampling 2D-LC Analysis of Mangosteen Pericarp Xanthones Using the Agilent 1290 Infinity II 2D-LC Solution

A high-resolution UHPLC analysis of xanthones present in the extracts of the pericarp of mangosteen (Garcinia mangostana L.) was carried out on an Agilent 1290 Infinity II LC. Excellent resolution and peak capacity (300 calculated at half height) were obtained within a total analysis time, including column reconditioning, of 16.5 minutes. The main xanthone (α-mangostin) was quantified in two ex...

متن کامل

Analysis of water-soluble vitamins from multivitamin tablets for nutrition labeling

In this Application Note we describe an application solution to carry out qualitative and quantitative analysis of water soluble vitamins. We developed a single and robust reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous determination of 10 different vitamins unlike a number of different traditional methods which quantify the components individually. Separ...

متن کامل

Analysis of Potential Genotoxic Arylamine and Aminopyridine Impurities in Active Pharmaceutical Ingredients Agilent 1290 Infinity LC system and Agilent 6460A Triple Quadrupole MS system for method development and fast analysis

This Application Note illustrates the possibilities of the Agilent 1290 Infinity LC system and the Agilent 6460A Triple Quadrupole Mass Spectrometer for quantitative analysis of potential genotoxic impurities (PGIs) in active pharmaceutical ingredients (APIs). A generic approach was used to determine arylamine and aminopyridine PGIs in selected APIs. The influence of column length and mobile ph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009